Loading…
Shaping ability of reciprocating and rotary systems in oval-shaped root canals: a microcomputed tomography study
This study compared the shaping ability of single-file reciprocating (WaveOne Gold) and multifile rotary (Mtwo) systems on mandibular oval-shaped canine root canals, using microcomputed tomography (micro-CT). Thirty mandibular canines were scanned by micro-CT and assigned to one of two groups (n=15)...
Saved in:
Published in: | Acta odontológica latinoamericana 2021-12, Vol.34 (3), p.282-288 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | eng ; por |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This study compared the shaping ability of single-file reciprocating (WaveOne Gold) and multifile rotary (Mtwo) systems on mandibular oval-shaped canine root canals, using microcomputed tomography (micro-CT). Thirty mandibular canines were scanned by micro-CT and assigned to one of two groups (n=15) according to the system used for root canal preparation: WaveOne Gold or Mtwo. After preparation, the teeth were rescanned, and the percentage of untouched canal area, apical transportation and centering ability were analyzed. The data was evaluated using Kruskal and Mann- Whitney tests (p0.05). WaveOne gold had less canal transportation than MTwo at the 5 mm section (p |
---|---|
ISSN: | 1852-4834 0326-4815 1852-4834 |
DOI: | 10.54589/aol.34/3/282 |