Loading…

Perioperative Deep Vein Thrombosis and D-dimer Measurement in Patients with Brain Tumor

We investigated the appropriate D-dimer cutoff value for each brain tumor type for acute or subacute deep vein thrombosis (DVT) following transcranial brain tumor surgery.In this single-center retrospective study, a cumulative total of 128 patients who underwent transcranial brain tumor surgery were...

Full description

Saved in:
Bibliographic Details
Published in:Neurologia Medico-Chirurgica 2022/04/15, Vol.62(4), pp.186-194
Main Authors: OKAMOTO, Emiko, ISHIKAWA, Eiichi, KINO, Hiroyoshi, KOHZUKI, Hidehiro, SUGII, Narushi, NAITO, Hiroyuki, HARA, Takuma, HOMMA, Satoshi, MATSUDA, Masahide, TSURUBUCHI, Takao, ISHIKAWA, Takaaki, KAWAKAMI, Yasushi, AKUTSU, Hiroyoshi
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We investigated the appropriate D-dimer cutoff value for each brain tumor type for acute or subacute deep vein thrombosis (DVT) following transcranial brain tumor surgery.In this single-center retrospective study, a cumulative total of 128 patients who underwent transcranial brain tumor surgery were enrolled and classified into the glioma group, the other intracranial malignant tumor group, and the intracranial benign tumor group. Venous ultrasonography was performed if the D-dimer plasma levels were positive (≥1 μg/mL) before surgery and on postoperative day (POD) 3 or 7.Of the 128 cases, DVT developed in 32 (25.0%). Among those, acute or subacute DVT was diagnosed in 22 cases on POD 3 and in 8 cases on POD 7. Compared with DVT-negative cases on POD 3, acute or subacute DVT-positive cases on POD 3 revealed a significant increase in the D-dimer level in all groups combined and in the benign tumor group but not in the glioma group. With regard to DVT on POD 3 in all groups, the receiver operating characteristic curve for the D-dimer level on POD 3 demonstrated a cutoff value of 3.3 μg/mL (sensitivity [0.636] and specificity [0.750]). However, if this cutoff value was used in practice, eight cases would be false-negative with a minimum D-dimer level of 1.5 μg/mL.The D-dimer cutoff value for acute or subacute DVT on POD 3 could be set to 3.3 μg/mL; however, the setting resulted in several false-negative cases. Practically, 1.5 μg/mL of the D-dimer cutoff value on POD 3 might be appropriate to avoid false-negative results.
ISSN:0470-8105
1349-8029
DOI:10.2176/jns-nmc.2021-0339