Loading…

Detection of β-alanyl aminopeptidase as a biomarker for Pseudomonas aeruginosa in the sputum of patients with cystic fibrosis using exogenous volatile organic compound evolution

A novel, rapid and sensitive analytical method has been developed and applied to 105 sputum samples from patients with cystic fibrosis, including 5 samples from post-lung transplant patients. This new method is specifically targeted to measure β-alanyl aminopeptidase activity which is characteristic...

Full description

Saved in:
Bibliographic Details
Published in:RSC advances 2020-03, Vol.10 (18), p.10634-10645
Main Authors: Thompson, Ryan, Stephenson, Dominic, Sykes, Hannah E, Perry, John D, Stanforth, Stephen P, Dean, John R
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A novel, rapid and sensitive analytical method has been developed and applied to 105 sputum samples from patients with cystic fibrosis, including 5 samples from post-lung transplant patients. This new method is specifically targeted to measure β-alanyl aminopeptidase activity which is characteristic of some important Gram-negative pathogens. Of relevance to this study are and pathogens of the complex both of which are commonly associated with respiratory infections as well as increased morbidity and mortality in adult cystic fibrosis patients. The analytical method involves the addition of a novel enzyme substrate ( 3-amino- -(3-fluorophenyl)propanamide) that interacts with β-alanyl aminopeptidase to generate an exogenous volatile organic compound 3-fluoroaniline (LOD 0.02 μg mL ; LOQ 0.06 μg mL ). 3-Fluoroaniline was determined at 20 times above its calculated limit of quantification in the sputum samples by HS-SPME-GC-MS and then the results compared with standard culture methods and bacterial identification using MALDI-TOF-MS. Detection of 3-fluoroaniline was possible after only 8 h incubation of the sputum samples with a 95% success rate; this increased to 100% at 24 h which was well within the typical routine timeframe of 48 h. To our knowledge, this is the first demonstration of detection of by use of a custom-designed substrate to liberate a detectable and unique VOC. The very high negative predictive value (100% in this study) means such an assay could be appropriate as a screening technique for patients who are not yet colonized by this pathogen.
ISSN:2046-2069
2046-2069
DOI:10.1039/c9ra08386c