Loading…

Repeatability of a Virtual Reality Headset Perimeter in Glaucoma and Ocular Hypertensive Patients

The VisuALL S is an automated, static threshold, virtual reality-based perimeter for mobile evaluation of the visual field. We examined same-day and 3-month repeatability.PurposeThe VisuALL S is an automated, static threshold, virtual reality-based perimeter for mobile evaluation of the visual field...

Full description

Saved in:
Bibliographic Details
Published in:Translational vision science & technology 2024-06, Vol.13 (6), p.14
Main Authors: Nascimento e Silva, Rafaella, Kim, Julia A., Li, Yihao, Chen, Chen, Chaudhry, Anisa F., Berneshawi, Andrew R., Zhang, Miao, Villarreal, Adam, Liu, Jocelyn, Shue, Ann, Chang, Dolly S., Chang, Robert T.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The VisuALL S is an automated, static threshold, virtual reality-based perimeter for mobile evaluation of the visual field. We examined same-day and 3-month repeatability.PurposeThe VisuALL S is an automated, static threshold, virtual reality-based perimeter for mobile evaluation of the visual field. We examined same-day and 3-month repeatability.Adult participants with a diagnosis of glaucoma or ocular hypertension underwent two VisuALL 24-2 Normal T- Full threshold strategy tests at baseline and one additional exam at 3 months for each eligible eye. Spearman, intraclass correlation coefficients (ICCs), and Bland-Altman plots were used to assess the correlation of individual point sensitivities and mean deviation (MD) among three tests.MethodsAdult participants with a diagnosis of glaucoma or ocular hypertension underwent two VisuALL 24-2 Normal T- Full threshold strategy tests at baseline and one additional exam at 3 months for each eligible eye. Spearman, intraclass correlation coefficients (ICCs), and Bland-Altman plots were used to assess the correlation of individual point sensitivities and mean deviation (MD) among three tests.Eighty-eight eyes (44 participants) were included. Average age was 68.1 ± 14.3 years, and 60.7% were male. VisuALL MD was highly correlated between tests (intravisit: r = 0.89, intervisit: r = 0.82; P < 0.001 for both). Bland-Altman analysis showed an average difference in intravisit MD of -0.67 dB (95% confidence interval [CI], -6.04 to 4.71 dB) and -0.15 dB (95% CI, -8.04 to 7.73 dB) for intervisit exams. Eight-five percent of pointwise intravisit ICCs were above 0.75 (range, 0.63 to 0.93), and 65% of pointwise intervisit ICCs were above 0.75 (range, 0.55 to 0.91).ResultsEighty-eight eyes (44 participants) were included. Average age was 68.1 ± 14.3 years, and 60.7% were male. VisuALL MD was highly correlated between tests (intravisit: r = 0.89, intervisit: r = 0.82; P < 0.001 for both). Bland-Altman analysis showed an average difference in intravisit MD of -0.67 dB (95% confidence interval [CI], -6.04 to 4.71 dB) and -0.15 dB (95% CI, -8.04 to 7.73 dB) for intervisit exams. Eight-five percent of pointwise intravisit ICCs were above 0.75 (range, 0.63 to 0.93), and 65% of pointwise intervisit ICCs were above 0.75 (range, 0.55 to 0.91).VisuALL demonstrated high correlation of MD between tests and good repeatability for individual point sensitivities among three tests in 3 months, except at the points around the blind spot and s
ISSN:2164-2591
2164-2591
DOI:10.1167/tvst.13.6.14