Loading…

Ultrasonographic reliability and repeatability of simultaneous bilateral assessment of diaphragm muscle thickness during normal breathing

BackgroundThe diaphragm is considered the main muscle involved in breathing and also linked to trunk stabilization functions. Up to date, rehabilitative ultrasound imaging (RUSI) has been the most used technique to evaluate unilaterally the transcostal diaphragm thickness. Nevertheless, the inspirat...

Full description

Saved in:
Bibliographic Details
Published in:Quantitative imaging in medicine and surgery 2023-10, Vol.13 (10), p.6656-6667
Main Authors: Molina-Hernández, Nerea, Chicharro, José López, Becerro-de-Bengoa-Vallejo, Ricardo, Losa-Iglesias, Marta Elena, Rodríguez-Sanz, David, Vicente-Campos, Davinia, Marugán-Rubio, Daniel, Gutiérrez-Torre, Samuel Eloy, Calvo-Lobo, César
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:BackgroundThe diaphragm is considered the main muscle involved in breathing and also linked to trunk stabilization functions. Up to date, rehabilitative ultrasound imaging (RUSI) has been the most used technique to evaluate unilaterally the transcostal diaphragm thickness. Nevertheless, the inspiratory activity of both hemi-diaphragms is bilaterally performed at the same time, and its simultaneous evaluation with a thoracic orthosis could improve its assessment as well as its re-education with visual biofeedback of both hemi-diaphragms at the same time. The purpose was to evaluate the reliability and repeatability of simultaneous thickness measurements of both hemi-diaphragms bilaterally during normal breathing using a thoracic orthosis that allowed bilateral fixation of both right and left ultrasound probes.MethodsThe study was conducted in 46 healthy subjects, whose diaphragm thickness was measured bilaterally and simultaneously in the anterior axillary line during relaxed breathing with a designed thoracic orthosis and 2 ultrasound tools. Intra-examiner (same examiner), inter-examiner (2 examiners), intra-session (1 hour) and inter-session (1 week) reliability and repeatability between each pair of measurements of diaphragm muscle thickness were analyzed during normal breathing.ResultsReliability and repeatability for intra-session evaluations using the thoracic orthosis were excellent to evaluate simultaneous thickness of both hemi-diaphragms by bilateral probes fixation (intraclass correlation coefficient =0.919-0.997; standard error of measurement =0.002-0.007 cm; minimum detectable change =0.006-0.020 cm), without systematic errors (P>0.05) between each pair of measurements. Nevertheless, inter-session evaluations varied from good to excellent using the bilateral probes fixation (intraclass correlation coefficient =0.614-0.984; standard error of measurement =0.006-0.028 cm; minimum detectable change =0.017-0.079 cm), although some systematic errors were presented (P
ISSN:2223-4292
2223-4306
DOI:10.21037/qims-23-329