Loading…

Impact of 64 multi-detector computed tomography for the evaluation of aortic paraprosthetic regurgitation

Summary Background Multi-detector computed tomography (MDCT) has been used to provide diagnostic information after heart valve replacements such as prosthetic valve dysfunction. However, only few data are available about aortic paraprosthetic regurgitation (APR). The aim of this study is to assess t...

Full description

Saved in:
Bibliographic Details
Published in:Journal of cardiology 2011-11, Vol.58 (3), p.294-299
Main Authors: Hara, Masahiko, MD, Nishino, Masami, MD, PhD, FJCC, Taniike, Masayuki, MD, PhD, Makino, Nobuhiko, MD, PhD, Kato, Hiroyasu, MD, Egami, Yasuyuki, MD, Shutta, Ryu, MD, Tanouchi, Jun, MD, PhD, FJCC, Hunatsu, Toshihiro, MD, PhD, Taniguchi, Kazuhiro, MD, PhD, Yamada, Yoshio, MD, PhD, FJCC
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Summary Background Multi-detector computed tomography (MDCT) has been used to provide diagnostic information after heart valve replacements such as prosthetic valve dysfunction. However, only few data are available about aortic paraprosthetic regurgitation (APR). The aim of this study is to assess the feasibility, accuracy, and reproducibility of the existence of APR using contrast-enhanced 64-row MDCT. Methods We retrospectively evaluated 20 consecutive patients who underwent both 64-row MDCT and two-dimensional transthoracic echocardiography (2D-TTE) after aortic valve replacement. The presence of APR was evaluated with 64-row MDCT, and validated with 2D-TTE, two-dimensional transesophageal echocardiography (2D-TEE), or intraoperative findings if available. If APR was present, we also evaluated paraprosthetic anatomical regurgitation orifice (PARO) area to quantify the prognostic impact of APR or for surgical planning such as closure device sizing. Results Overall, 12 of 20 valves showed beam-hardening artifact (BHA) which made the reliable evaluation of APR difficult. The presence of artifact seemed to depend on valve types. Among 8 patients who did not show BHA, there were perfect agreements between MDCT and 2D-TTE, 2D-TEE, or intra-operative findings about APR. There were excellent inter-observer agreements in the evaluation of APR and PARO area. PARO area was consistent with the echocardiographic severity of APR in this study. Conclusions Our retrospective data suggest that MDCT could be a reliable technique for the evaluation of APR after On-X standard or SJM standard valve replacement. MDCT can become a novel quantitative tool for the evaluation of PARO area.
ISSN:0914-5087
1876-4738
DOI:10.1016/j.jjcc.2011.08.002