Rupture of anterior cruciate ligament monitored by acoustic emission

The scope of this study is to relate the acoustic emission (AE) during rupture of human soft tissue (anterior cruciate ligament, ACL) to the mechanisms leading to its failure. The cumulative AE activity highlights the onset of serious damage, while other parameters, show repeatable tendencies, being...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of the Acoustical Society of America 2011-06, Vol.129 (6), p.EL217-EL222
Main Authors: Aggelis, D. G., Paschos, N. K., Barkoula, N. M., Paipetis, A. S., Matikas, T. E., Georgoulis, A. D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The scope of this study is to relate the acoustic emission (AE) during rupture of human soft tissue (anterior cruciate ligament, ACL) to the mechanisms leading to its failure. The cumulative AE activity highlights the onset of serious damage, while other parameters, show repeatable tendencies, being well correlated with the tissue's mechanical behavior. The frequency content of AE signals increases throughout the experiment, while other indices characterize between different modes of failure. Results of this preliminary study show that AE can shed light into the failure process of this tissue, and provide useful data on the ACL reconstruction.
ISSN:0001-4966
1520-8524
DOI:10.1121/1.3571537