Internal temperature measurement of an ytterbium doped material under laser operation

Temperature of the pumped volume of an ytterbium doped material has been measured while laser action is taking place. This is achieved by recording green emissions at 530 and 550 nm from Er3+ impurities. These emissions result from energy transfer upconversion processes between Yb3+ and Er3+. Experi...

Full description

Saved in:
Bibliographic Details
Published in:Optics express 2011-01, Vol.19 (2), p.1138-1146
Main Authors: Petit, J, Viana, B, Goldner, Ph
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Temperature of the pumped volume of an ytterbium doped material has been measured while laser action is taking place. This is achieved by recording green emissions at 530 and 550 nm from Er3+ impurities. These emissions result from energy transfer upconversion processes between Yb3+ and Er3+. Experiments performed on a Yb3+:CaGdAlO4 crystal show the effect of pump power and laser wavelength on the sample internal temperature. Temperature variation along the sample length has also been measured. This method can complement data obtained by thermal cameras which can only access surface temperatures in most laser materials.