Loading…
Continuous thermodilution cardiac output measurement in sheep
A technique has been developed to continuously measure cardiac output by means of the principles of thermodilution. Pulmonary artery catheters were modified by placing a 10 cm filament near the usual injectate port. Small amounts of heat were infused according to a randomly repeating binary on-off s...
Saved in:
Published in: | The Journal of thoracic and cardiovascular surgery 1992-08, Vol.104 (2), p.315-320 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A technique has been developed to continuously measure cardiac output by means of the principles of thermodilution. Pulmonary artery catheters were modified by placing a 10 cm filament near the usual injectate port. Small amounts of heat were infused according to a randomly repeating binary on-off sequence. The distal blood temperature was recorded and cross-correlated with the heat waveform to produce a dilution curve and calculate cardiac output. The technique was compared with bolus thermodilution in seven sheep. Cardiac output ranged from 1.5 to 13.2 L/min, and heart rate varied from 59 to 180 beats/min. The linear regression between the data obtained by the two methods is represented by the equation y = 1.00x + 0.13; the correlation coefficient, R, is 0.97, and the p value is |
---|---|
ISSN: | 0022-5223 1097-685X |
DOI: | 10.1016/S0022-5223(19)34783-X |