Loading…
Corrosion monitoring in Nigerian petroleum industry: A case study of Kaduna petroleum refinery
Corrosion monitoring in a petroleum refinery was carried out using coupon test method. Five different locations were selected along the pipeline of the cooling water section of the refinery. Analysis revealed that there was corrosion taking place at different rates within the refinery. The lowest ra...
Saved in:
Published in: | Indian journal of engineering and materials sciences 2002-10, Vol.9 (5), p.335-338 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Corrosion monitoring in a petroleum refinery was carried out using coupon test method. Five different locations were selected along the pipeline of the cooling water section of the refinery. Analysis revealed that there was corrosion taking place at different rates within the refinery. The lowest rate recorded was 14 mg dm super(-2) day super(-1) and the highest rate was 42 mg dm super(-2) day super(-1). It is recommended that the chemical dosage of corrosion inhibitors be improved and that a constant monitoring program be adopted. |
---|---|
ISSN: | 0971-4588 |