Generic control method of multileg voltage-source-converters for fast practical implementation
A generic and simple control method is suggested for any multileg voltage-source-converter. A specific coding yields an inversion table allowing a fast practical implementation. Phase-to-phase voltage references have to be defined for such a table. This original control strategy is validated by expe...
Saved in:
Published in: | IEEE transactions on power electronics 2003-03, Vol.18 (2), p.517-526 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A generic and simple control method is suggested for any multileg voltage-source-converter. A specific coding yields an inversion table allowing a fast practical implementation. Phase-to-phase voltage references have to be defined for such a table. This original control strategy is validated by experimental results for two-leg, three-leg, four-leg, and five-leg structures supplying balanced and unbalanced multiphase loads. |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/TPEL.2003.809349 |