Comparison of Charpy-V and J-Integral Transition Temperature Shifts in CrMoV Pressure Vessel Steels
Both Charpy-V and precracked Charpy-size specimens were included in the original surveillance programme of the Loviisa nuclear power plant pressure vessel made of CrMoV steel. With precracked specimens the J-value at the onset of brittle fracture was determined as a function of temperature and irrad...
Saved in:
Published in: | The International journal of pressure vessels and piping 1993-01, Vol.55 (1), p.81-88 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Both Charpy-V and precracked Charpy-size specimens were included in the original surveillance programme of the Loviisa nuclear power plant pressure vessel made of CrMoV steel. With precracked specimens the J-value at the onset of brittle fracture was determined as a function of temperature and irradiation dose. The irradiation induced transition temperature shifts measured with Charpy-V and precracked three-point bend specimens are correlated by using indexed temperature values. The shapes of brittle fracture transition curves measured with the fracture mechanical specimens both for the irradiated and non-irradiated material state are compared using a statistical brittle fracture model. |
---|---|
ISSN: | 0308-0161 |
DOI: | 10.1016/0308-0161(93)90048-X |