Loading…

Diagnostic performance of the Kaiser score for characterizing lesions on breast MRI with comparison to a multiparametric classification system

•The Kaiser score has high diagnostic accuracy in breast magnetic resonance imaging.•The interobserver agreement for the Kaiser score was excellent.•The use of the Kaiser score may reduce the biopsy rate for true negative lesions. To determine the diagnostic performance of the Kaiser score and to co...

Full description

Saved in:
Bibliographic Details
Published in:European journal of radiology 2021-05, Vol.138, p.109659-109659, Article 109659
Main Authors: Istomin, Aleksandr, Masarwah, Amro, Vanninen, Ritva, Okuma, Hidemi, Sudah, Mazen
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c404t-a413d148717cd00ca2ace9520fe5ec758a8b68723fe15570b60a50a764fffb8d3
cites cdi_FETCH-LOGICAL-c404t-a413d148717cd00ca2ace9520fe5ec758a8b68723fe15570b60a50a764fffb8d3
container_end_page 109659
container_issue
container_start_page 109659
container_title European journal of radiology
container_volume 138
creator Istomin, Aleksandr
Masarwah, Amro
Vanninen, Ritva
Okuma, Hidemi
Sudah, Mazen
description •The Kaiser score has high diagnostic accuracy in breast magnetic resonance imaging.•The interobserver agreement for the Kaiser score was excellent.•The use of the Kaiser score may reduce the biopsy rate for true negative lesions. To determine the diagnostic performance of the Kaiser score and to compare it with the BI-RADS–based multiparametric classification system (MCS). Two breast radiologists, blinded to the clinical and pathological information, separately evaluated a database of 499 consecutive patients with structural 3.0 T breast MRI and 697 histopathologically verified lesions. The Kaiser scores and corresponding MCS categories were recorded. The sensitivity and specificity of the Kaiser score and the MCS categories to differentiate benign from malignant lesions were calculated. The interobserver reproducibility and receiver operating characteristic (ROC) parameters were analysed. The sensitivity and specificity of the MCS were 100 % and 12 %, respectively, and those of the Kaiser score were 98.5 % and 34.8 % for reader 1 and 98.7 % and 47.5 % for reader 2. The area under the ROC-curve was 85.9 and 87.6 for readers 1 and 2. The interobserver intraclass correlation coefficient was excellent at 0.882. Reader 1 upgraded six lesions from BI-RADS 3 to a Kaiser score of >4, and reader 2 upgraded seven lesions. When applying the Kaiser score to 158 benign lesions readers 1 and 2 would have reduced the biopsy rate by 22.8 % and 35.4 %, respectively. The Kaiser score showed high diagnostic accuracy with excellent interobserver reproducibility. The MCS had perfect sensitivity but low specificity. Although the Kaiser score had slightly lower sensitivity, its specificity was 3–4 times greater than that of the MCS. Thus, the Kaiser score has the potential to considerably reduce the biopsy rate for true negative lesions.
doi_str_mv 10.1016/j.ejrad.2021.109659
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_2504340349</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0720048X2100139X</els_id><sourcerecordid>2504340349</sourcerecordid><originalsourceid>FETCH-LOGICAL-c404t-a413d148717cd00ca2ace9520fe5ec758a8b68723fe15570b60a50a764fffb8d3</originalsourceid><addsrcrecordid>eNp9UcFu1DAQtRCIbgtfgIR85JLFdpw4OXBALS0VRUgIJG7WxBl3vUrixeMFtR_Rb8ZlS4-cRjPzZp7ee4y9kmIthWzfbte4TTCulVCyTPq26Z-wleyMqoxR5ilbCaNEJXT344gdE22FEI3u1XN2VNemUaVdsbuzANdLpBwc32HyMc2wOOTR87xB_gkCYeLkYkJeltxtIIHLmMJtWK75hBTiQjwufEgIlPnnr5f8d8gb7uK8gxSorHLkwOf9lEOZwIw5FTY3AVHwwUEuLzjdUMb5BXvmYSJ8-VBP2PfzD99OP1ZXXy4uT99fVU4LnSvQsh6l7ow0bhTCgQKHfZHksUFnmg66oS1G1B5l0xgxtAIaAabV3vuhG-sT9ubwd5fizz1StnMgh9MEC8Y9WdUIXWtR675A6wPUpUiU0NtdCjOkGyuFvQ_Cbu3fIOx9EPYQRLl6_UCwH2YcH2_-OV8A7w4ALDJ_BUyWXMBi_RgSumzHGP5L8AdtwJ3C</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2504340349</pqid></control><display><type>article</type><title>Diagnostic performance of the Kaiser score for characterizing lesions on breast MRI with comparison to a multiparametric classification system</title><source>ScienceDirect Journals</source><creator>Istomin, Aleksandr ; Masarwah, Amro ; Vanninen, Ritva ; Okuma, Hidemi ; Sudah, Mazen</creator><creatorcontrib>Istomin, Aleksandr ; Masarwah, Amro ; Vanninen, Ritva ; Okuma, Hidemi ; Sudah, Mazen</creatorcontrib><description>•The Kaiser score has high diagnostic accuracy in breast magnetic resonance imaging.•The interobserver agreement for the Kaiser score was excellent.•The use of the Kaiser score may reduce the biopsy rate for true negative lesions. To determine the diagnostic performance of the Kaiser score and to compare it with the BI-RADS–based multiparametric classification system (MCS). Two breast radiologists, blinded to the clinical and pathological information, separately evaluated a database of 499 consecutive patients with structural 3.0 T breast MRI and 697 histopathologically verified lesions. The Kaiser scores and corresponding MCS categories were recorded. The sensitivity and specificity of the Kaiser score and the MCS categories to differentiate benign from malignant lesions were calculated. The interobserver reproducibility and receiver operating characteristic (ROC) parameters were analysed. The sensitivity and specificity of the MCS were 100 % and 12 %, respectively, and those of the Kaiser score were 98.5 % and 34.8 % for reader 1 and 98.7 % and 47.5 % for reader 2. The area under the ROC-curve was 85.9 and 87.6 for readers 1 and 2. The interobserver intraclass correlation coefficient was excellent at 0.882. Reader 1 upgraded six lesions from BI-RADS 3 to a Kaiser score of &gt;4, and reader 2 upgraded seven lesions. When applying the Kaiser score to 158 benign lesions readers 1 and 2 would have reduced the biopsy rate by 22.8 % and 35.4 %, respectively. The Kaiser score showed high diagnostic accuracy with excellent interobserver reproducibility. The MCS had perfect sensitivity but low specificity. Although the Kaiser score had slightly lower sensitivity, its specificity was 3–4 times greater than that of the MCS. Thus, the Kaiser score has the potential to considerably reduce the biopsy rate for true negative lesions.</description><identifier>ISSN: 0720-048X</identifier><identifier>EISSN: 1872-7727</identifier><identifier>DOI: 10.1016/j.ejrad.2021.109659</identifier><identifier>PMID: 33752000</identifier><language>eng</language><publisher>Ireland: Elsevier B.V</publisher><subject>BI-RADS ; Breast - diagnostic imaging ; Breast cancer ; Breast Neoplasms - diagnostic imaging ; Humans ; Magnetic Resonance Imaging ; Multiparametric MRI ; Radiography ; Reproducibility of Results ; Retrospective Studies ; ROC Curve ; Scoring system ; Sensitivity and Specificity</subject><ispartof>European journal of radiology, 2021-05, Vol.138, p.109659-109659, Article 109659</ispartof><rights>2021 Elsevier B.V.</rights><rights>Copyright © 2021 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c404t-a413d148717cd00ca2ace9520fe5ec758a8b68723fe15570b60a50a764fffb8d3</citedby><cites>FETCH-LOGICAL-c404t-a413d148717cd00ca2ace9520fe5ec758a8b68723fe15570b60a50a764fffb8d3</cites><orcidid>0000-0001-5325-2699 ; 0000-0003-2423-9350 ; 0000-0001-8749-1268</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,786,790,27957,27958</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33752000$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Istomin, Aleksandr</creatorcontrib><creatorcontrib>Masarwah, Amro</creatorcontrib><creatorcontrib>Vanninen, Ritva</creatorcontrib><creatorcontrib>Okuma, Hidemi</creatorcontrib><creatorcontrib>Sudah, Mazen</creatorcontrib><title>Diagnostic performance of the Kaiser score for characterizing lesions on breast MRI with comparison to a multiparametric classification system</title><title>European journal of radiology</title><addtitle>Eur J Radiol</addtitle><description>•The Kaiser score has high diagnostic accuracy in breast magnetic resonance imaging.•The interobserver agreement for the Kaiser score was excellent.•The use of the Kaiser score may reduce the biopsy rate for true negative lesions. To determine the diagnostic performance of the Kaiser score and to compare it with the BI-RADS–based multiparametric classification system (MCS). Two breast radiologists, blinded to the clinical and pathological information, separately evaluated a database of 499 consecutive patients with structural 3.0 T breast MRI and 697 histopathologically verified lesions. The Kaiser scores and corresponding MCS categories were recorded. The sensitivity and specificity of the Kaiser score and the MCS categories to differentiate benign from malignant lesions were calculated. The interobserver reproducibility and receiver operating characteristic (ROC) parameters were analysed. The sensitivity and specificity of the MCS were 100 % and 12 %, respectively, and those of the Kaiser score were 98.5 % and 34.8 % for reader 1 and 98.7 % and 47.5 % for reader 2. The area under the ROC-curve was 85.9 and 87.6 for readers 1 and 2. The interobserver intraclass correlation coefficient was excellent at 0.882. Reader 1 upgraded six lesions from BI-RADS 3 to a Kaiser score of &gt;4, and reader 2 upgraded seven lesions. When applying the Kaiser score to 158 benign lesions readers 1 and 2 would have reduced the biopsy rate by 22.8 % and 35.4 %, respectively. The Kaiser score showed high diagnostic accuracy with excellent interobserver reproducibility. The MCS had perfect sensitivity but low specificity. Although the Kaiser score had slightly lower sensitivity, its specificity was 3–4 times greater than that of the MCS. Thus, the Kaiser score has the potential to considerably reduce the biopsy rate for true negative lesions.</description><subject>BI-RADS</subject><subject>Breast - diagnostic imaging</subject><subject>Breast cancer</subject><subject>Breast Neoplasms - diagnostic imaging</subject><subject>Humans</subject><subject>Magnetic Resonance Imaging</subject><subject>Multiparametric MRI</subject><subject>Radiography</subject><subject>Reproducibility of Results</subject><subject>Retrospective Studies</subject><subject>ROC Curve</subject><subject>Scoring system</subject><subject>Sensitivity and Specificity</subject><issn>0720-048X</issn><issn>1872-7727</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9UcFu1DAQtRCIbgtfgIR85JLFdpw4OXBALS0VRUgIJG7WxBl3vUrixeMFtR_Rb8ZlS4-cRjPzZp7ee4y9kmIthWzfbte4TTCulVCyTPq26Z-wleyMqoxR5ilbCaNEJXT344gdE22FEI3u1XN2VNemUaVdsbuzANdLpBwc32HyMc2wOOTR87xB_gkCYeLkYkJeltxtIIHLmMJtWK75hBTiQjwufEgIlPnnr5f8d8gb7uK8gxSorHLkwOf9lEOZwIw5FTY3AVHwwUEuLzjdUMb5BXvmYSJ8-VBP2PfzD99OP1ZXXy4uT99fVU4LnSvQsh6l7ow0bhTCgQKHfZHksUFnmg66oS1G1B5l0xgxtAIaAabV3vuhG-sT9ubwd5fizz1StnMgh9MEC8Y9WdUIXWtR675A6wPUpUiU0NtdCjOkGyuFvQ_Cbu3fIOx9EPYQRLl6_UCwH2YcH2_-OV8A7w4ALDJ_BUyWXMBi_RgSumzHGP5L8AdtwJ3C</recordid><startdate>202105</startdate><enddate>202105</enddate><creator>Istomin, Aleksandr</creator><creator>Masarwah, Amro</creator><creator>Vanninen, Ritva</creator><creator>Okuma, Hidemi</creator><creator>Sudah, Mazen</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0001-5325-2699</orcidid><orcidid>https://orcid.org/0000-0003-2423-9350</orcidid><orcidid>https://orcid.org/0000-0001-8749-1268</orcidid></search><sort><creationdate>202105</creationdate><title>Diagnostic performance of the Kaiser score for characterizing lesions on breast MRI with comparison to a multiparametric classification system</title><author>Istomin, Aleksandr ; Masarwah, Amro ; Vanninen, Ritva ; Okuma, Hidemi ; Sudah, Mazen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c404t-a413d148717cd00ca2ace9520fe5ec758a8b68723fe15570b60a50a764fffb8d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>BI-RADS</topic><topic>Breast - diagnostic imaging</topic><topic>Breast cancer</topic><topic>Breast Neoplasms - diagnostic imaging</topic><topic>Humans</topic><topic>Magnetic Resonance Imaging</topic><topic>Multiparametric MRI</topic><topic>Radiography</topic><topic>Reproducibility of Results</topic><topic>Retrospective Studies</topic><topic>ROC Curve</topic><topic>Scoring system</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Istomin, Aleksandr</creatorcontrib><creatorcontrib>Masarwah, Amro</creatorcontrib><creatorcontrib>Vanninen, Ritva</creatorcontrib><creatorcontrib>Okuma, Hidemi</creatorcontrib><creatorcontrib>Sudah, Mazen</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Istomin, Aleksandr</au><au>Masarwah, Amro</au><au>Vanninen, Ritva</au><au>Okuma, Hidemi</au><au>Sudah, Mazen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Diagnostic performance of the Kaiser score for characterizing lesions on breast MRI with comparison to a multiparametric classification system</atitle><jtitle>European journal of radiology</jtitle><addtitle>Eur J Radiol</addtitle><date>2021-05</date><risdate>2021</risdate><volume>138</volume><spage>109659</spage><epage>109659</epage><pages>109659-109659</pages><artnum>109659</artnum><issn>0720-048X</issn><eissn>1872-7727</eissn><notes>ObjectType-Article-1</notes><notes>SourceType-Scholarly Journals-1</notes><notes>ObjectType-Feature-2</notes><notes>content type line 23</notes><abstract>•The Kaiser score has high diagnostic accuracy in breast magnetic resonance imaging.•The interobserver agreement for the Kaiser score was excellent.•The use of the Kaiser score may reduce the biopsy rate for true negative lesions. To determine the diagnostic performance of the Kaiser score and to compare it with the BI-RADS–based multiparametric classification system (MCS). Two breast radiologists, blinded to the clinical and pathological information, separately evaluated a database of 499 consecutive patients with structural 3.0 T breast MRI and 697 histopathologically verified lesions. The Kaiser scores and corresponding MCS categories were recorded. The sensitivity and specificity of the Kaiser score and the MCS categories to differentiate benign from malignant lesions were calculated. The interobserver reproducibility and receiver operating characteristic (ROC) parameters were analysed. The sensitivity and specificity of the MCS were 100 % and 12 %, respectively, and those of the Kaiser score were 98.5 % and 34.8 % for reader 1 and 98.7 % and 47.5 % for reader 2. The area under the ROC-curve was 85.9 and 87.6 for readers 1 and 2. The interobserver intraclass correlation coefficient was excellent at 0.882. Reader 1 upgraded six lesions from BI-RADS 3 to a Kaiser score of &gt;4, and reader 2 upgraded seven lesions. When applying the Kaiser score to 158 benign lesions readers 1 and 2 would have reduced the biopsy rate by 22.8 % and 35.4 %, respectively. The Kaiser score showed high diagnostic accuracy with excellent interobserver reproducibility. The MCS had perfect sensitivity but low specificity. Although the Kaiser score had slightly lower sensitivity, its specificity was 3–4 times greater than that of the MCS. Thus, the Kaiser score has the potential to considerably reduce the biopsy rate for true negative lesions.</abstract><cop>Ireland</cop><pub>Elsevier B.V</pub><pmid>33752000</pmid><doi>10.1016/j.ejrad.2021.109659</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0001-5325-2699</orcidid><orcidid>https://orcid.org/0000-0003-2423-9350</orcidid><orcidid>https://orcid.org/0000-0001-8749-1268</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0720-048X
ispartof European journal of radiology, 2021-05, Vol.138, p.109659-109659, Article 109659
issn 0720-048X
1872-7727
language eng
recordid cdi_proquest_miscellaneous_2504340349
source ScienceDirect Journals
subjects BI-RADS
Breast - diagnostic imaging
Breast cancer
Breast Neoplasms - diagnostic imaging
Humans
Magnetic Resonance Imaging
Multiparametric MRI
Radiography
Reproducibility of Results
Retrospective Studies
ROC Curve
Scoring system
Sensitivity and Specificity
title Diagnostic performance of the Kaiser score for characterizing lesions on breast MRI with comparison to a multiparametric classification system
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-09-21T19%3A43%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Diagnostic%20performance%20of%20the%20Kaiser%20score%20for%20characterizing%20lesions%20on%20breast%20MRI%20with%20comparison%20to%20a%20multiparametric%20classification%20system&rft.jtitle=European%20journal%20of%20radiology&rft.au=Istomin,%20Aleksandr&rft.date=2021-05&rft.volume=138&rft.spage=109659&rft.epage=109659&rft.pages=109659-109659&rft.artnum=109659&rft.issn=0720-048X&rft.eissn=1872-7727&rft_id=info:doi/10.1016/j.ejrad.2021.109659&rft_dat=%3Cproquest_cross%3E2504340349%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c404t-a413d148717cd00ca2ace9520fe5ec758a8b68723fe15570b60a50a764fffb8d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2504340349&rft_id=info:pmid/33752000&rfr_iscdi=true