Loading…

Performance of commercially-available cholesterol self-tests

Background Hypercholesterolemia (plasma cholesterol concentration ≥5.2 mmol/L) is a risk factor for cardiovascular disease and stroke. Many different cholesterol self-tests are readily available at general stores, pharmacies and web shops. However, there is limited information on their analytical an...

Full description

Saved in:
Bibliographic Details
Published in:Annals of clinical biochemistry 2021-07, Vol.58 (4), p.289-296
Main Authors: Kurstjens, Steef, Gemen, Eugenie, Walk, Selina, Njo, Tjin, Krabbe, Johannes, Gijzen, Karlijn, Elisen, Marc GLM, Kusters, Ron
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Hypercholesterolemia (plasma cholesterol concentration ≥5.2 mmol/L) is a risk factor for cardiovascular disease and stroke. Many different cholesterol self-tests are readily available at general stores, pharmacies and web shops. However, there is limited information on their analytical and diagnostic performance. Methods We included 62 adult patients who required a lipid panel measurement (cholesterol, high-density lipoprotein (HDL), triglycerides and LDLcalc) for routine care. The performance of five different cholesterol self-tests, three quantitative meters (Roche Accutrend Plus, Mission 3-in-1 and Qucare) and two semi-quantitative strip tests (Veroval and Mylan MyTest), was assessed according to the manufacturers’ protocol. Results The average plasma cholesterol concentration was 5.2 ± 1.2 mmol/L. The mean absolute relative difference (MARD) of the five cholesterol self-tests ranged from 6 ± 5% (Accutrend Plus) to 20 ± 12% (Mylan Mytest). The Accutrend Plus cholesterol meter showed the best diagnostic performance with a 92% sensitivity and 89% specificity. The Qucare and Mission 3-in-1 are able to measure HDL concentrations and can thus provide a cholesterol:HDL ratio. The Passing-Bablok regression analyses for the ratio showed poor performance in both self-tests (Mission 3-in-1: y = 1.62x–1.20; Qucare: y = 0.61x + 1.75). The Accutrend Plus is unable to measure the plasma high-density lipoprotein concentration. Conclusions/interpretation: The Accutrend Plus cholesterol meter (Roche) had excellent diagnostic and analytic performance. However, several of the commercially-available self-tests had considerably poor accuracy and diagnostic performance and therefore do not meet the required qualifications, potentially leading to erroneous results. Better regulation, standardization and harmonization of cholesterol self-tests is warranted.
ISSN:0004-5632
1758-1001