Fault tolerant system based on non-integers order observers: Application in a heat exchanger
This work presents a fault-tolerant (FT) scheme based on the application of non-integer order observers also called fractional observers, the case of study is a double pipe countercurrent heat exchanger (HE). The aim of the FT is to detect sensors faults as soon as possible, and to provide a healthy...
Saved in:
Published in: | ISA transactions 2018-09, Vol.80, p.286-296 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This work presents a fault-tolerant (FT) scheme based on the application of non-integer order observers also called fractional observers, the case of study is a double pipe countercurrent heat exchanger (HE). The aim of the FT is to detect sensors faults as soon as possible, and to provide a healthy signal in order to replace the faulty sensor signal by the fractional observer estimation. To develop the FT scheme a bank of high gain fractional order observers (HGFOO) is proposed. The Riemann-Liouville (RL) fractional derivative definition is used to solve each fractional observer. Experimental measures from a HE were used to test the performance of the fractional observers and the control scheme. The results show the robustness of the proposed observers.
•Fractional high-gain observers design.•Fault toleran system based on fractional observers.•The robustness of the fractional observers to sensor faults. |
---|---|
ISSN: | 0019-0578 1879-2022 |
DOI: | 10.1016/j.isatra.2018.06.007 |