Loading…
Characterization of Curing Emissions from Conversion Varnishes
Three commercially available conversion varnish coating "systems" (stain, sealer, and topcoat) were selected for an initial scoping study. The total volatile content of the catalyzed varnishes, as determined by U.S. Environmental Protection Agency (EPA) Method 24, ranged from 64 to 73 weig...
Saved in:
Published in: | Journal of the Air & Waste Management Association (1995) 1999-01, Vol.49 (1), p.70-75 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Three commercially available conversion varnish coating "systems" (stain, sealer, and topcoat) were selected for an initial scoping study. The total volatile content of the catalyzed varnishes, as determined by U.S. Environmental Protection Agency (EPA) Method 24, ranged from 64 to 73 weight%. Uncombined (free) formaldehyde concentrations, determined by a sodium sulfite titration method, ranged from 0.15 to 0.58 weight% of the uncatalyzed varnishes. Each sealer and topcoat was also analyzed by gas chromatography (EPA Method 311). The primary volatile organic constituents included methyl ethyl ketone (MEK), isobutanol, n-butanol, methyl isobutyl ketone (MIBK), toluene, ethylbenzene, the xylenes, and 1,2,4-trimethylbenzene. |
---|---|
ISSN: | 1096-2247 2162-2906 |
DOI: | 10.1080/10473289.1999.10463777 |