Comparative dosimetry for radon and thoron in high background radiation areas in China
The present study focuses on internal exposure caused by the inhalation of radon and thoron progenies because the internal exposures have not yet been clarified. For their dose assessment, radon, thoron and thoron progeny concentrations were measured by passive monitors over a long period (for 6 mon...
Saved in:
Published in: | Radiation protection dosimetry 2015-11, Vol.167 (1-3), p.155-159 |
---|---|
Main Authors: | , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The present study focuses on internal exposure caused by the inhalation of radon and thoron progenies because the internal exposures have not yet been clarified. For their dose assessment, radon, thoron and thoron progeny concentrations were measured by passive monitors over a long period (for 6 months). Consequently, radon, thoron and equilibrium equivalent thoron concentrations were given as 124 ± 78, 1247 ± 1189 and 7.8 ± 9.1 Bq m(-3), respectively. Annual effective doses are estimated to be 3.1 ± 2.0 mSv for radon and 2.2 ± 2.5 mSv for thoron. Total dose are estimated to be 5.3 ± 3.5 mSv a(-1). The present study has revealed that the radon dose was comparable with the thoron dose, and the total dose was ∼2 times higher than the worldwide average. |
---|---|
ISSN: | 0144-8420 1742-3406 |
DOI: | 10.1093/rpd/ncv235 |