Effective prevention of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip arthroplasty using a posterior lip augmentation device
Purpose This retrospective study was performed to determine the effectiveness of preventing recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device (PLAD). Methods Between January 2003 and Dezember 2006, 27 PLADs were used in...
Saved in:
Published in: | Archives of orthopaedic and trauma surgery 2016-04, Vol.136 (4), p.579-583 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
This retrospective study was performed to determine the effectiveness of preventing recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device (PLAD).
Methods
Between January 2003 and Dezember 2006, 27 PLADs were used in the treatment of recurrent hip dislocation in 27 patients who had received a cemented primary total hip arthroplasty using Endo-MarkIII/SP2 (Waldemar LINK, Hamburg, Germany) components. The mean number of dislocations prior to stabilization with this specific device was 2.6 (range 2–4, SD ± 0.4) with a mean time to revision surgery of 10 months (IQR 13). The mean age of the patients at time of revision surgery was 81.5 years (range 70–94, SD ± 6.9). The control group evaluating the clinical outcome using the Harris Hip Score (HHS) also received a cemented primary total hip arthroplasty using the same implants. A retrospective clinical and radiological review was carried out at a mean follow-up of 68.5 months (range 30–103, SD ± 17.7).
Results
Of the 27 patients, 6 had died at the time of the latest review, with the posterior lip augmentation device still in situ and without reported further dislocation after PLAD application. In 2 of the remaining 21 patients recurrent dislocation occurred, thus a subsequent revision of respective implants had to be performed to achieve persistent joint stability. At latest follow-up no deep infection or implant loosening occurred.
Conclusion
Surgical treatment of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device is a safe and effective procedure which can lead to a secondary stabilization of the total hip arthroplasty in about 90 % of the patients. |
---|---|