Loading…

Effective prevention of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip arthroplasty using a posterior lip augmentation device

Purpose This retrospective study was performed to determine the effectiveness of preventing recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device (PLAD). Methods Between January 2003 and Dezember 2006, 27 PLADs were used in...

Full description

Saved in:
Bibliographic Details
Published in:Archives of orthopaedic and trauma surgery 2016-04, Vol.136 (4), p.579-583
Main Authors: Schmidl, S., Jakobs, O., Guenther, D., Lausmann, C., Schoof, B., Beckmann, J., Gehrke, T., Gebauer, M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purpose This retrospective study was performed to determine the effectiveness of preventing recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device (PLAD). Methods Between January 2003 and Dezember 2006, 27 PLADs were used in the treatment of recurrent hip dislocation in 27 patients who had received a cemented primary total hip arthroplasty using Endo-MarkIII/SP2 (Waldemar LINK, Hamburg, Germany) components. The mean number of dislocations prior to stabilization with this specific device was 2.6 (range 2–4, SD ± 0.4) with a mean time to revision surgery of 10 months (IQR 13). The mean age of the patients at time of revision surgery was 81.5 years (range 70–94, SD ± 6.9). The control group evaluating the clinical outcome using the Harris Hip Score (HHS) also received a cemented primary total hip arthroplasty using the same implants. A retrospective clinical and radiological review was carried out at a mean follow-up of 68.5 months (range 30–103, SD ± 17.7). Results Of the 27 patients, 6 had died at the time of the latest review, with the posterior lip augmentation device still in situ and without reported further dislocation after PLAD application. In 2 of the remaining 21 patients recurrent dislocation occurred, thus a subsequent revision of respective implants had to be performed to achieve persistent joint stability. At latest follow-up no deep infection or implant loosening occurred. Conclusion Surgical treatment of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device is a safe and effective procedure which can lead to a secondary stabilization of the total hip arthroplasty in about 90 % of the patients.
ISSN:0936-8051
1434-3916