Evaluating Component Migration After Modular Stem Fixed-Bearing Total Ankle Replacement
Abstract To date, no studies have evaluated implant migration after implantation of a modular stem fixed-bearing total ankle replacement. The purpose of the present report was to determine the inter-rater and intrarater reliability of our proposed measurement technique and to assess implant migratio...
Saved in:
Published in: | The Journal of foot and ankle surgery 2015-05, Vol.54 (3), p.326-331 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract To date, no studies have evaluated implant migration after implantation of a modular stem fixed-bearing total ankle replacement. The purpose of the present report was to determine the inter-rater and intrarater reliability of our proposed measurement technique and to assess implant migration over time. Twenty consecutive patients (aged 59.3 ± 12.2 years) who had undergone implantation with this modern, third-generation prosthetic were included. To assess implant migration, measurements were made from non-weightbearing, postoperative radiographs immediately after surgery and again at 1 year and 2 years. Implant migration was defined as a change in implant location from the immediate postoperative radiograph. The proposed measurement technique appears to be a reliable method of assessing implant migration, evidenced by the high inter-rater reliability and intrarater reliability (intraclass correlation [2,1] 0.993 and intraclass correlation [1,1] 0.997, respectively). The mean implant migration was 0.7 mm at 1 year and 1.0 mm at 2 years. Time ( r = 0.42) and gender ( r = 0.31) were significant predictors of implant migration (R2 = 0.27, p = .008). Therefore, we confirmed our hypothesis that implant migration would significantly increase over time and discovered that implant migration was greater in males (1.2 ± 1.1 mm) than females (0.1 ± 0.8 mm). Given the gross stability of the implant and lack of revision within the follow-up period, the measurements obtained could serve as clinical guidelines for acceptable implant migration in the short term. To determine the thresholds correlated with implant failure, future studies with long-term follow-up are warranted. |
---|---|
ISSN: | 1067-2516 1542-2224 |