Loading…
Comparative study of the dynamic glass transition temperature by DMA and TMDSC
Measurements of the glass transition temperature obtained by dynamic mechanical analysis (DMA) and temperature modulated differential scanning calorimetry (TMDSC) are reported to be different. This was mainly attributed to the frequency effect. To obtain comparable measurements, experimental conditi...
Saved in:
Published in: | Polymer testing 2010-12, Vol.29 (8), p.1002-1006 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Measurements of the glass transition temperature obtained by dynamic mechanical analysis (DMA) and temperature modulated differential scanning calorimetry (TMDSC) are reported to be different. This was mainly attributed to the frequency effect. To obtain comparable measurements, experimental conditions were studied. Although some experimental issues had to be fixed, it was possible to apply the same frequency and temperature using quasi-isothermal conditions in both instruments. The method was tested with three different polymer samples. It was then found that when choosing a suitable response parameter, i.e. the phase angle, the dynamic glass transition temperature values obtained by both methods are practically the same. |
---|---|
ISSN: | 0142-9418 1873-2348 |
DOI: | 10.1016/j.polymertesting.2010.09.005 |