Multiple model estimator based detection of abnormal cell overheating in a Li-ion battery string with minimum number of temperature sensors
This paper proposes modeling of abnormal cell overheating caused by internal short circuit in a cell of a Li-ion battery string by augmenting the cell state space model with unknown input disturbance. Furthermore, with minimum number of temperature sensors, in order to identify which of the cells in...
Saved in:
Published in: | Journal of power sources 2015, Vol.273, p.1171-1181 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper proposes modeling of abnormal cell overheating caused by internal short circuit in a cell of a Li-ion battery string by augmenting the cell state space model with unknown input disturbance. Furthermore, with minimum number of temperature sensors, in order to identify which of the cells in the string is experiencing the abnormal overheating, a multiple model estimator (MME) is used. Simulation results demonstrate that the proposed MME can detect the abnormally overheating cell as well as quickly detect that an abnormal overheating event occurred in the battery string. |
---|---|
ISSN: | 0378-7753 1873-2755 |
DOI: | 10.1016/j.jpowsour.2014.09.166 |