Loading…

Determination of the fungicide picoxystrobin using anodic stripping voltammetry on a metal film modified glassy carbon electrode

[Display omitted] ► Picoxystrobin was determined by adsorptive voltammetry in urine and water. ► Bi mediated the electrocatalysis of picoxyxtrobin. ► Bi film is proven to be at the surface of the GCE even when operating at positive potentials. ► Experimental conditions were adjusted for trace determ...

Full description

Saved in:
Bibliographic Details
Published in:Electrochimica acta 2013-05, Vol.97, p.202-209
Main Authors: Dornellas, Rafael M., Franchini, Rômulo A.A., Aucelio, Ricardo Q.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:[Display omitted] ► Picoxystrobin was determined by adsorptive voltammetry in urine and water. ► Bi mediated the electrocatalysis of picoxyxtrobin. ► Bi film is proven to be at the surface of the GCE even when operating at positive potentials. ► Experimental conditions were adjusted for trace determination. ► SPE eliminated interferences from urine and pre-concentrated the analyte. Differential pulse anodic stripping voltammetry was used for trace determination of picoxystrobin in urine and water samples. Experimental conditions have been optimized and the measurement cycle started with the application of a deposition potential at −700mV, during 60s, for the in situ formation of the Bi film on a glassy carbon substrate and the accumulation of the analyte. It has been proven that, in the conditions employed, a significant amount of Bi is still present as a film on the surface electrode when the anodic scan is performed from +790 to +1050mV at a rate of 40mVs−1 and that the presence of Bi is fundamental for the accumulation and oxidation of picoxystrobin during re-dissolution (peak maximum at +954mV). The supporting electrolyte was HCl 1molL−1 and a cleaning procedure was developed in order to minimize memory effects. Linear and homoscedastic analytical responses (r2>0.99) have been observed with limit of quantification of 100μgkg−1. Solid phase extraction (on a C-18 cartridge) allows the pre-concentration of the analyte and eliminates interferences from urine samples. Recoveries from 89.3 to 104.8% were found and interferences from azoxystrobin, dimoxistrobin, fluxastrobin, kresoxi-methyl and pyraclostrobin were evaluated.
ISSN:0013-4686
1873-3859
DOI:10.1016/j.electacta.2013.02.125