PKP-034 Determination of methotrexate in CSF by chemiluminescence using the architect

BackgroundIntrathecal administration of methotrexate (MTX) in the treatment of different neoplastic diseases to prevent relapses in the CNS and the need to keep MTX concentrations in CSF during infusion of MTX requires study of the pharmacokinetics of MTX at this level. It is therefore necessary to...

Full description

Saved in:
Bibliographic Details
Published in:European journal of hospital pharmacy. Science and practice 2016-03, Vol.23 (Suppl 1), p.A193-A194
Main Authors: Montejano-Hervás, P, Reyes-Torres, I, Aumente, MD
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:BackgroundIntrathecal administration of methotrexate (MTX) in the treatment of different neoplastic diseases to prevent relapses in the CNS and the need to keep MTX concentrations in CSF during infusion of MTX requires study of the pharmacokinetics of MTX at this level. It is therefore necessary to measure concentrations of MTX in CSF.PurposeTo evaluate the validity (selectivity, accuracy and precision) of MTX measurements in CSF using a chemiluminescence assay for determination of MTX in plasma and to discard the matrix effect which might occur when measuring MTX in CSF.Material and methodsDifferent concentrations of MTX were tested in different types of samples to evaluate the selectivity and discard the matrix effect. To the studied matrix (CSF) were added increasing and known amounts of plasma with MTX (addition standard) and the results were correlated with the regression equation of the data obtained in both matrices. Accuracy was obtained by comparing the results of both matrices and obtaining the relative error. Due to the limitation of the small volume of CSF obtained in each extraction we were unable to perform different analyses on the same sample of CSF. 10 measurements on the same CSF sample containing a known quantity of MTX (obtained in our own test control) to evaluate precision were performed.ResultsFactor analysis of standard additions gave the regression line X=0.00233+1.0105Y. The correlation coefficient was r = 0.99 and the relative error was -2.3%. The series of 10 repetitions of CSF with a known concentration (436 μM) gave an average value of 445.44 μM (424–464 μM), with SD of 12.5 and a variation coefficient of 2.8%.ConclusionThe good selectivity, accuracy and precision of the CFS analysis by CMIA (Architect) gave reliable data on concentrations of MTX in CSF, highlighting the absence of the matrix effect.No conflict of interest.
ISSN:2047-9956
2047-9964
DOI:10.1136/ejhpharm-2016-000875.437