Compact 810 kA linear transformer driver cavity

We are performing experiments with a 92-kV, 810-kA, 74.6-GW linear transformer driver (LTD) cavity. This cavity generates a ∼100ns power pulse from DC-charged capacitors in a single step. Our experiments start with an existing 100-kV, 490-kA LTD cavity and are making a number of improvements to it t...

Full description

Saved in:
Bibliographic Details
Published in:Physical review special topics. PRST-AB. Accelerators and beams 2011-04, Vol.14 (4), p.040401, Article 040401
Main Authors: Woodworth, J. R., Fowler, W. E., Stoltzfus, B. S., Stygar, W. A., Sceiford, M. E., Mazarakis, M. G., Anderson, H. D., Harden, M. J., Blickem, J. R., White, R., Kim, A. A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We are performing experiments with a 92-kV, 810-kA, 74.6-GW linear transformer driver (LTD) cavity. This cavity generates a ∼100ns power pulse from DC-charged capacitors in a single step. Our experiments start with an existing 100-kV, 490-kA LTD cavity and are making a number of improvements to it that are aimed at increasing the cavity’s peak output power and better understanding its operation. We are making improvements to the gas switches, the capacitors, and the magnetic toroids as well as heavily instrumenting the cavity. These experiments have increased the cavity’s output current into a matched load by 65% without increasing its volume.