Loading…

Design, performance evaluation and analysis of the inlet tube of pressure sensor for chamber pressure measurement

Purpose In Aerospace applications, the inlet tubes are used to mount strain gauge type pressure sensors on the engine under static test to measure engine chamber pressure. This paper aims to focus on the limitations of the inlet tube and its design aspects to serve better in the static test environm...

Full description

Saved in:
Bibliographic Details
Published in:Sensor review 2019-07, Vol.39 (4), p.612-621
Main Authors: Gobi, K, Kannapiran, B, Devaraj, D, Valarmathi, K
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purpose In Aerospace applications, the inlet tubes are used to mount strain gauge type pressure sensors on the engine under static test to measure engine chamber pressure. This paper aims to focus on the limitations of the inlet tube and its design aspects to serve better in the static test environment. The different sizes of the inlet tubes are designed to meet the static test and safety requirements. This paper presents the performance evaluation of the designed inlet tubes with calibration results and the selection criteria of the inlet tube to measure combustion chamber pressure with the specified accuracy during static testing of engines. Design/methodology/approach Two sensors, specifically, one cavity type pressure sensor with the inlet tube of range 0-6.89 MPa having natural frequency of the diaphragm 17 KHz and another flush diaphragm type pressure sensor of the same range having −3 dB frequency response, 5 KHz are mounted on the same pressure port of the engine under static test to study the shortcomings of the inlet tube. The limitations of the inlet tube have been analyzed to aid the tube design. The different sizes of inlet tubes are designed, fabricated and tested to study the effect of the inlet tube on the performance of the pressure sensor. The dynamic calibration is used for this purpose. The dynamic parameters of the sensor with the designed tubes are calculated and analyzed to meet the static test requirements. The diaphragm temperature test is conducted on the representative hardware of pressure sensor with and without inlet tube to analyze the effect of the inlet tube against the temperature error. The inlet tube design is validated through the static test to gain confidence on measurement. Findings The cavity type pressure sensor failed to capture the pressure peak, whereas the flush diaphragm type pressure sensor captured the pressure peak of the engine under a static test. From the static test data and dynamic calibration results, the bandwidth of cavity type sensor with tube is much lower than the required bandwidth (five times the bandwidth of the measurand), and hence, the cavity type sensor did not capture the pressure peak data. The dynamic calibration results of the pressure sensor with and without an inlet tube show that the reduction of the bandwidth of the pressure sensor is mainly due to the inlet tube. From the analysis of dynamic calibration results of the sensor with the designed inlet tubes of different sizes, it is s
ISSN:0260-2288
1758-6828
DOI:10.1108/SR-12-2017-0260