Loading…

Experimental study of an earthquake-resilient prefabricated opening-web steel channel beam-to-column joint with flange cover plates

•An innovative earthquake-resilient POWSCBCJ with FCPs are proposed.•Eight specimens are subjected to low-cyclic loading tests and repair tests.•Several seismic behavior indices and failure modes of specimens are obtained.•It is useful to replace connecting devices for achieving rapid repair of stru...

Full description

Saved in:
Bibliographic Details
Published in:Engineering structures 2020-10, Vol.221, p.111054, Article 111054
Main Authors: Jiang, Zi-Qin, Kang, Yi-Tao, Liu, Xue-Chun, Cheng, Kui-Kui, Chen, Xin
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•An innovative earthquake-resilient POWSCBCJ with FCPs are proposed.•Eight specimens are subjected to low-cyclic loading tests and repair tests.•Several seismic behavior indices and failure modes of specimens are obtained.•It is useful to replace connecting devices for achieving rapid repair of structures.•Hysteretic performance of the joint is stable, which can be used as a damper. Post-earthquake structural repair combined with prefabricated steel structures is an important aspect of repairing buildings damaged by earthquakes and has been extensively studied by earthquake engineering scholars. Based on the concept of plastic damage concentration and replaceable damage elements, and considering the convenience of floor assembly and pipeline pavement, an innovative earthquake-resilient prefabricated opening-web steel channel beam-to-column joint (POWSCBCJ) with flange cover plates (FCPs) was proposed in this paper. By varying four influencing parameters and applying three loading protocols, eight low-frequency cyclic loading tests were carried out on eight full-scale specimens of a new type of earthquake-resilient POWSCBCJ. The seismic behavior and earthquake-resilient performance were evaluated by varying parameters such as the thickness of the FCPs, bolt spacing in the middle row, width of the dog-bone reduced sections, number of bolts, and loading system. The experimental results show that the thickness of the FCPs is the main factor affecting the yielding load and bearing capacity of the joint. In addition, an appropriate number of connecting bolts on the FCP and the bolt spacing in the middle row are conducive to improving the energy dissipation ability of the specimen. At the same time, the hysteretic performance of the joint is stable during the process of equal amplitude loading, indicating that it can be used as a damper.
ISSN:0141-0296
1873-7323
DOI:10.1016/j.engstruct.2020.111054