Loading…
Detection of Electron Radiation Pulses Generated by a Subnanosecond Accelerator
— The characteristics of the electron beam generated by a subnanosecond accelerator with double sharpening in the voltage-pulse shaping circuit have been recorded. The duration of the electron-beam current pulse was 240–270 ps, the current amplitude was approximately 1.5 kА, and the maximum electron...
Saved in:
Published in: | Instruments and experimental techniques (New York) 2019-10, Vol.62 (4), p.528-531 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | —
The characteristics of the electron beam generated by a subnanosecond accelerator with double sharpening in the voltage-pulse shaping circuit have been recorded. The duration of the electron-beam current pulse was 240–270 ps, the current amplitude was approximately 1.5 kА, and the maximum electron energy was approximately 0.95 MeV. The pulse-response characteristics of SPPD29k and SPPD29-02 X-ray semiconductor detectors were determined: their full widths at the half-maximum τ
0.5
were approximately 320±30 and 450±30 ps, respectively. |
---|---|
ISSN: | 0020-4412 1608-3180 |
DOI: | 10.1134/S002044121903014X |