Loading…

Optical technologies towards improving the Far-infrared laser Polarimeter-Interferometer system on HL-2A tokamak

•The optical setup integrated by a lens and a high-sensitivity Pyroelectric Array Camera was applied to the alignment of the HCOOH laser in HL-2APolarimeter-Interferometer (PIer) system.•Spurious intermediate frequency (IF) mixed in the interferometry beat signal was verified in practice, and can be...

Full description

Saved in:
Bibliographic Details
Published in:Fusion engineering and design 2018-12, Vol.137, p.137-142
Main Authors: Li, Y.G., Zhou, Y., Ding, W.X., Li, Y., Wang, H.X., Yi, J., Deng, Z.C., Yuan, B.S., Yao, K., Yu, L.M., Zhang, Y.P., Huang, Z.H., Shi, Z.B., Liu, Yi, Yang, Q.W., Xu, M., Duan, X.R.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•The optical setup integrated by a lens and a high-sensitivity Pyroelectric Array Camera was applied to the alignment of the HCOOH laser in HL-2APolarimeter-Interferometer (PIer) system.•Spurious intermediate frequency (IF) mixed in the interferometry beat signal was verified in practice, and can be effectively eliminated by using a special adjustment method, based on the single-polarization response characteristic of the Schottky diode detector.•Spurious oscillation mixed in the Faraday rotation angle on HL-2A was verified to be mainly caused by the feedback lights reflected from the detector surface.•Experimental results on HL-2A validated that the unwanted feedback lights can be suppressed by employing the optic-isolator which was composed of a polarizer and a quarter-wave plate. Since the first performance of the HCOOH laser Polarimeter-Interferometer (PIer) in 2015 HL-2A experimental campaign, several optical technologies have been applied to improve the PIer system, including: (1) Optical alignment of the HCOOH laser at the long distance was implemented by the optical setup integrated by a lens and a high-sensitivity Pyroelectric Array Camera. (2) Due to application of the orthogonal waves transmission in the PIer system, some spurious intermediate frequency (IF) might be generated in the interferometry beat signal. For this problem, an effective optical adjustment method based on the single-polarization response characteristic of the Schottky diode detector was summarized in practice. (3) For double-passing type Faraday-effect polarimeter, analysis indicated that the severe oscillation disturbance in Faraday rotation angle was mainly caused by the stray lights or the feedback lights. Experimental results on HL-2A successfully validated that the unwanted feedback lights mainly came from the detector surface and was able to be effectively suppressed by the optic-isolator which was composed of a polarizer and a quarter-wave plate.
ISSN:0920-3796
1873-7196
DOI:10.1016/j.fusengdes.2018.09.003