Performance of fast-ion loss diagnostic on EAST
The scintillator-based detector for fast-ion loss measurements has been installed on EAST. To obtain high temporal resolution for fast-ion loss diagnostics, fast photomultiplier tube systems have been developed which can supply the complementary measurements to the previous image system with good en...
Saved in:
Published in: | Review of scientific instruments 2018-10, Vol.89 (10), p.10I144-10I144 |
---|---|
Main Authors: | , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The scintillator-based detector for fast-ion loss measurements has been installed on EAST. To obtain high temporal resolution for fast-ion loss diagnostics, fast photomultiplier tube systems have been developed which can supply the complementary measurements to the previous image system with good energy and pitch resolution by using a CCD camera. By applying the rotatable platform, the prompt losses of beam-ions can be measured in normal and reverse magnetic field. The thick-target bremsstrahlung occurring in the stainless steel shield with energetic electrons can produce X-rays, which will strike on the scintillator based detector. To understand this interference on fast-ion loss signals, the effects of energetic electrons on the scintillator-based detector are studied, including runaway electrons in the plasma ramping-up phase and fast electrons accelerated by the lower hybrid wave. |
---|---|
ISSN: | 0034-6748 1089-7623 |
DOI: | 10.1063/1.5038782 |