Loading…

Separatrix radius measurement of field-reversed configuration plasma in FRX-L

Magnetic pickup coils and single turn flux loops are installed on the FRX-L device. The combination of the two measurements provides the excluded flux radius that approximates the separatrix radius of the field-reversed configuration (FRC) plasma. Arrays of similar probes are used to map out local m...

Full description

Saved in:
Bibliographic Details
Published in:Review of Scientific Instruments 2004-10, Vol.75 (10), p.4289-4292
Main Authors: Zhang, S. Y., Tejero, E. M., Taccetti, J. M., Wurden, G. A., Intrator, T. P., Waganaar, W. J., Perkins, R.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Magnetic pickup coils and single turn flux loops are installed on the FRX-L device. The combination of the two measurements provides the excluded flux radius that approximates the separatrix radius of the field-reversed configuration (FRC) plasma. Arrays of similar probes are used to map out local magnetic field dynamics beyond both ends of the theta-coil confinement region to help understand the effects of cusp locations on flux trapping during the FRC formation process. Details on the probe design and system calibrations are presented. The overall system calibration of excluded flux radius measurement is examined by replacing FRC plasma with a known radius aluminum conductor cylinder.
ISSN:0034-6748
1089-7623
DOI:10.1063/1.1789618