Loading…
Proton versus Photon Breath-Hold Radiation for Left-Sided Breast Cancer after Breast-Conserving Surgery: A Dosimetric Comparison
Radiation to breast, chest wall, and/or regional nodes is an integral component of breast cancer management in many situations. Irradiating left-sided breast and/or regional nodes may be technically challenging because of cardiac tolerance and subsequent risk of long-term cardiac complications. Deep...
Saved in:
Published in: | International journal of particle therapy 2021, Vol.7 (3), p.24-33 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Radiation to breast, chest wall, and/or regional nodes is an integral component of breast cancer management in many situations. Irradiating left-sided breast and/or regional nodes may be technically challenging because of cardiac tolerance and subsequent risk of long-term cardiac complications. Deep inspiratory breath-hold (DIBH) technique physically separates cardiac structures away from radiation target volume, thus reducing cardiac dose with either photon (Ph) or proton beam therapy (PBT). The utility of combining PBT with DIBH is less well understood.
We compared photon-DIBH (Ph-DIBH) versus proton DIBH (Pr-DIBH) for different planning parameters, including target coverage and organ at risk (OAR) sparing. Necessary ethical permission was obtained from the institutional review board. Ten previous patients with irradiated, intact, left-sided breast and Ph-DIBH were replanned with PBT for dosimetric comparison. Clinically relevant normal OARs were contoured, and Ph plans were generated with parallel, opposed tangent beams and direct fields for supraclavicular and/or axillae whenever required. For proton planning, all targets were delineated individually and best possible coverage of planning target volume was achieved. Dose-volume histogram was analyzed to determine the difference in doses received by different OARs. Minimum and maximum dose (
and
) as well as dose received by a specific volume of OAR were compared. Each patient's initial plan (Ph-DIBH) was used as a control for comparing newly devised PBT plan (Pr-DIBH). Matched, paired
tests were applied to determine any significant differences between the 2 plans.
Both the plans were adequate in target coverage. Dose to cardiac structure subunits and ipsilateral lung were significantly reduced with the proton breath-hold technique. Significant dose reduction with Pr-DIBH was observed in comparison to Ph-DIBH for mean dose (
) to the heart (0.23 Gy versus 1.19 Gy;
  |
---|---|
ISSN: | 2331-5180 2331-5180 |
DOI: | 10.14338/IJPT-20-00026.1 |