Loading…

A low-molecular-weight oil cleaner for removal of leftover silicone oil intraocular tamponade

Silicone oil (SO) has been used as a long-term intraocular tamponade in treating retinal diseases for more than half a decade. However, its propensity to form tiny SO droplets is associated with a number of complications. Currently there is no effective way to remove such droplets from the eye cavit...

Full description

Saved in:
Bibliographic Details
Published in:Investigative ophthalmology & visual science 2015-01, Vol.56 (2), p.1014-1022
Main Authors: Chan, Yau Kei, Wong, David, Yeung, Hiu Kwan, Man, Ping Kwan, Shum, Ho Cheung
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Silicone oil (SO) has been used as a long-term intraocular tamponade in treating retinal diseases for more than half a decade. However, its propensity to form tiny SO droplets is associated with a number of complications. Currently there is no effective way to remove such droplets from the eye cavity. In this work, a novel cleaner was developed for effective removal of these droplets. The cleaner promotes the formation of an oil-in-water-in-oil (O/W/O) double-emulsion that consists of the unwanted droplets as the innermost oil phase. The cleaner's ability to encapsulate SO droplets was tested using both in vitro microdevices and ex vivo porcine eye models. The efficiency of the cleaner in removing the SO droplets was quantified using the three-dimensional (3D) printed eye model. Both the volatility and in vitro cytotoxicity of the cleaner were evaluated on three retinal cell lines. Cleaner 1.0 is volatile and has an evaporation rate of 0.14 mL/h at room temperature. The formation of O/W/O double-emulsion indicates the encapsulation of SO droplets by the cleaner. In the 3D printed eye model, rinsing with cleaner 1.0 led to a significant reduction of leftover SO droplets compared with 1Ă— phosphate-buffered saline (PBS; P < 0.05; n = 6). Cleaner 1.0 did not cause significant cell death (3%-6%) compared with balance salt solution (BSS; 1%-3%) in all three cell lines. The reduction in the cell viability due to cleaner 1.0, relative to that of BSS, was significant only in ARPE-19 cells (27%; P < 0.05) but not in the other two cell lines (8% and 17%, respectively; P > 0.05). The double-emulsification approach was effective in removing remnant droplets from the eye cavities, and the cleaner was compatible with common cell types encountered in human eyes. The mechanism of toxicity of the proposed cleaner is still unknown, therefore, further in vivo animal tests are needed for full evaluation of the physiological response before the proposed cleaner can be advanced to clinical trials for retinal surgeries.
ISSN:0146-0404
1552-5783
DOI:10.1167/iovs.14-15061