Loading…

Fabrication and non-destructive characterization of through-plastic-via (TPV) in flexible hybrid electronics

Abstract Flexible hybrid electronics (FHE) have been gaining interest in recent years as this technology has the potential to become a low-cost, mechanically pliable sister technology for multilayer printed circuit boards (PCBs). One of the limitations of rigid PCB is low endurance to mechanical ben...

Full description

Saved in:
Bibliographic Details
Published in:Flexible and printed electronics 2021-06, Vol.6 (2), p.25001
Main Authors: Sondhi, Kartik, Avuthu, Sai Guruva Reddy, Richstein, Jörg, Fan, Z Hugh, Nishida, Toshikazu
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Flexible hybrid electronics (FHE) have been gaining interest in recent years as this technology has the potential to become a low-cost, mechanically pliable sister technology for multilayer printed circuit boards (PCBs). One of the limitations of rigid PCB is low endurance to mechanical bending, this limitation poses a threat to the efficacy for wearable applications. During bending, a substrate experiences both compressive and tensile stress. These stresses are similar in magnitude but opposite in direction. This difference in directionality creates a non-linear stress gradient in a via which impacts the structural integrity, endurance and bending reliability of a circuit during its operation. Additionally, as flexible substrates can be bent to a higher bending radius, the magnitude of maximum extrinsic stresses observed on flexible substrates could be higher than the stress observed on rigid substrates. Hence, the reliability and mechanical compliance of through-hole-plastic-vias for reliable flexible circuits need to be understood. In this study, we have developed a process to create vias on flexible substrates using a rapid commercial laser (Nd-YaG laser) to study the effects on via resistance due to three different variables—bending stresses, via diameter and via length. A novel non-destructive approach (CT-scanner) was used to scan the via structures and determine the filling for all via diameters from 50 to 450 µ m and via lengths of 7, 10 mils. Two different configurations of vias were used to measure and analyze the effect of mechanical cycling on via resistance and via filling. This demonstration of electrical and mechanical testing of vias and novel methodologies for via filling, and via electrical resistance can contribute to better design and fabrication guidelines of multi-layer FHE circuits.
ISSN:2058-8585
2058-8585
DOI:10.1088/2058-8585/abeb58