A method for the correction of AVHRR onboard IR calibration in the event of short-term radiative contamination

We analysed the operational infrared (IR) calibration of the AVHRR radiometers onboard NOAA-12, 14 and 15 satellites. It was shown that solar blackbody contamination affects the calibration of all IR channels. This source of error in the calibration may result in uncertainties in the estimation of s...

Full description

Saved in:
Bibliographic Details
Published in:International journal of remote sensing 2001-01, Vol.22 (17), p.3619-3624
Main Authors: Trishchenko, A. P., Li, Z.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We analysed the operational infrared (IR) calibration of the AVHRR radiometers onboard NOAA-12, 14 and 15 satellites. It was shown that solar blackbody contamination affects the calibration of all IR channels. This source of error in the calibration may result in uncertainties in the estimation of sea surface temperature (SST) up to 0.5 K or more. We propose an approach to correct this error using a Fourier transform filtering technique.