Pulsed discharge regeneration of diesel particulate filters
A novel method for the removal of soot from a diesel particulate filter using pulsed electric discharges is presented. High voltage pulses of between 18 and 25 kV of nano to microsecond duration and with pulse energies of typically 100–200 mJ were applied to the filter via a series spark gap. Initia...