Loading…
Assessing image quality in effective Poisson's ratio elastography and poroelastography: II
Poroelastography is a novel elastographic technique for imaging the time variation of the mechanical behaviour of poroelastic materials. Poroelastograms are generated as a series of time-sequenced effective Poisson's ratio (EPR) elastograms, obtained from the imaged material under sustained com...
Saved in:
Published in: | Physics in medicine & biology 2007-03, Vol.52 (5), p.1321-1333 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c373t-5218199a148a4e081e0c3dccd7188b102fb4cff00c33800f700a65240fe4a95a3 |
---|---|
cites | cdi_FETCH-LOGICAL-c373t-5218199a148a4e081e0c3dccd7188b102fb4cff00c33800f700a65240fe4a95a3 |
container_end_page | 1333 |
container_issue | 5 |
container_start_page | 1321 |
container_title | Physics in medicine & biology |
container_volume | 52 |
creator | Righetti, Raffaella Ophir, Jonathan Kumar, Arun Thitai Krouskop, Thomas A |
description | Poroelastography is a novel elastographic technique for imaging the time variation of the mechanical behaviour of poroelastic materials. Poroelastograms are generated as a series of time-sequenced effective Poisson's ratio (EPR) elastograms, obtained from the imaged material under sustained compression. In the companion report (Righetti et al 2007 Phys. Med. Biol. 52 1303), we investigated image quality of EPR elastography starting from a theoretical analysis of the performance limitations of axial strain elastography and lateral strain elastography. In this report, we extend this analysis to poroelastography. The theoretical analysis reported in these two companion papers allows understanding the performance limitations of these novel techniques and identifying the fundamental parameters that control their signal-to-noise ratio, contrast-to-noise ratio and resolution. The results of these studies also indicate that EPR elastograms and poroelastograms of reasonable image quality can be generated in practical applications that may be of clinical interest provided that advanced elastographic techniques in combination with other commonly employed imaging methods to increase signal-to-noise and contrast-to-noise ratios are used. |
doi_str_mv | 10.1088/0031-9155/52/5/008 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_69010042</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>69010042</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-5218199a148a4e081e0c3dccd7188b102fb4cff00c33800f700a65240fe4a95a3</originalsourceid><addsrcrecordid>eNqNkE9Lw0AUxBdRbK1-AQ-yJ8VD7HvZbLLxVop_CgU96MXLst3s1pU0G7OJ0G9vSosKvXh6zPCbgTeEnCPcIAgxBmAY5cj5mMdj3ktxQIbIUoxSnsIhGf4AA3ISwgcAooiTYzLAjAEmPBuSt0kIJgRXLalbqaWhn50qXbumrqLGWqNb92Xos3ch-Ooq0Ea1zlNTqtD6ZaPq9zVVVUFr3_i_5i2dzU7JkVVlMGe7OyKv93cv08do_vQwm07mkWYZayMeo8A8V5gIlRgQaECzQusiQyEWCLFdJNpa6F0mAGwGoFIeJ2BNonKu2Ihcbnvrxn92JrRy5YI2Zakq47sg0xwQIIl7MN6CuvEhNMbKuumfbtYSQW4WlZvB5GYwyWPJeyn60MWuvVusTPEb2U3YA9EWcL7-X-H1Pr_Pybqw7Btby4uM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>69010042</pqid></control><display><type>article</type><title>Assessing image quality in effective Poisson's ratio elastography and poroelastography: II</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Righetti, Raffaella ; Ophir, Jonathan ; Kumar, Arun Thitai ; Krouskop, Thomas A</creator><creatorcontrib>Righetti, Raffaella ; Ophir, Jonathan ; Kumar, Arun Thitai ; Krouskop, Thomas A</creatorcontrib><description>Poroelastography is a novel elastographic technique for imaging the time variation of the mechanical behaviour of poroelastic materials. Poroelastograms are generated as a series of time-sequenced effective Poisson's ratio (EPR) elastograms, obtained from the imaged material under sustained compression. In the companion report (Righetti et al 2007 Phys. Med. Biol. 52 1303), we investigated image quality of EPR elastography starting from a theoretical analysis of the performance limitations of axial strain elastography and lateral strain elastography. In this report, we extend this analysis to poroelastography. The theoretical analysis reported in these two companion papers allows understanding the performance limitations of these novel techniques and identifying the fundamental parameters that control their signal-to-noise ratio, contrast-to-noise ratio and resolution. The results of these studies also indicate that EPR elastograms and poroelastograms of reasonable image quality can be generated in practical applications that may be of clinical interest provided that advanced elastographic techniques in combination with other commonly employed imaging methods to increase signal-to-noise and contrast-to-noise ratios are used.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/0031-9155/52/5/008</identifier><identifier>PMID: 17301457</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Algorithms ; Computer Simulation ; Elasticity ; Image Enhancement - methods ; Image Interpretation, Computer-Assisted - methods ; Models, Biological ; Porosity ; Reproducibility of Results ; Sensitivity and Specificity ; Stress, Mechanical ; Ultrasonography - methods</subject><ispartof>Physics in medicine & biology, 2007-03, Vol.52 (5), p.1321-1333</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-5218199a148a4e081e0c3dccd7188b102fb4cff00c33800f700a65240fe4a95a3</citedby><cites>FETCH-LOGICAL-c373t-5218199a148a4e081e0c3dccd7188b102fb4cff00c33800f700a65240fe4a95a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,786,790,27957,27958</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17301457$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Righetti, Raffaella</creatorcontrib><creatorcontrib>Ophir, Jonathan</creatorcontrib><creatorcontrib>Kumar, Arun Thitai</creatorcontrib><creatorcontrib>Krouskop, Thomas A</creatorcontrib><title>Assessing image quality in effective Poisson's ratio elastography and poroelastography: II</title><title>Physics in medicine & biology</title><addtitle>Phys Med Biol</addtitle><description>Poroelastography is a novel elastographic technique for imaging the time variation of the mechanical behaviour of poroelastic materials. Poroelastograms are generated as a series of time-sequenced effective Poisson's ratio (EPR) elastograms, obtained from the imaged material under sustained compression. In the companion report (Righetti et al 2007 Phys. Med. Biol. 52 1303), we investigated image quality of EPR elastography starting from a theoretical analysis of the performance limitations of axial strain elastography and lateral strain elastography. In this report, we extend this analysis to poroelastography. The theoretical analysis reported in these two companion papers allows understanding the performance limitations of these novel techniques and identifying the fundamental parameters that control their signal-to-noise ratio, contrast-to-noise ratio and resolution. The results of these studies also indicate that EPR elastograms and poroelastograms of reasonable image quality can be generated in practical applications that may be of clinical interest provided that advanced elastographic techniques in combination with other commonly employed imaging methods to increase signal-to-noise and contrast-to-noise ratios are used.</description><subject>Algorithms</subject><subject>Computer Simulation</subject><subject>Elasticity</subject><subject>Image Enhancement - methods</subject><subject>Image Interpretation, Computer-Assisted - methods</subject><subject>Models, Biological</subject><subject>Porosity</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Stress, Mechanical</subject><subject>Ultrasonography - methods</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNqNkE9Lw0AUxBdRbK1-AQ-yJ8VD7HvZbLLxVop_CgU96MXLst3s1pU0G7OJ0G9vSosKvXh6zPCbgTeEnCPcIAgxBmAY5cj5mMdj3ktxQIbIUoxSnsIhGf4AA3ISwgcAooiTYzLAjAEmPBuSt0kIJgRXLalbqaWhn50qXbumrqLGWqNb92Xos3ch-Ooq0Ea1zlNTqtD6ZaPq9zVVVUFr3_i_5i2dzU7JkVVlMGe7OyKv93cv08do_vQwm07mkWYZayMeo8A8V5gIlRgQaECzQusiQyEWCLFdJNpa6F0mAGwGoFIeJ2BNonKu2Ihcbnvrxn92JrRy5YI2Zakq47sg0xwQIIl7MN6CuvEhNMbKuumfbtYSQW4WlZvB5GYwyWPJeyn60MWuvVusTPEb2U3YA9EWcL7-X-H1Pr_Pybqw7Btby4uM</recordid><startdate>20070307</startdate><enddate>20070307</enddate><creator>Righetti, Raffaella</creator><creator>Ophir, Jonathan</creator><creator>Kumar, Arun Thitai</creator><creator>Krouskop, Thomas A</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20070307</creationdate><title>Assessing image quality in effective Poisson's ratio elastography and poroelastography: II</title><author>Righetti, Raffaella ; Ophir, Jonathan ; Kumar, Arun Thitai ; Krouskop, Thomas A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-5218199a148a4e081e0c3dccd7188b102fb4cff00c33800f700a65240fe4a95a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Algorithms</topic><topic>Computer Simulation</topic><topic>Elasticity</topic><topic>Image Enhancement - methods</topic><topic>Image Interpretation, Computer-Assisted - methods</topic><topic>Models, Biological</topic><topic>Porosity</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Stress, Mechanical</topic><topic>Ultrasonography - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Righetti, Raffaella</creatorcontrib><creatorcontrib>Ophir, Jonathan</creatorcontrib><creatorcontrib>Kumar, Arun Thitai</creatorcontrib><creatorcontrib>Krouskop, Thomas A</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine & biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Righetti, Raffaella</au><au>Ophir, Jonathan</au><au>Kumar, Arun Thitai</au><au>Krouskop, Thomas A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessing image quality in effective Poisson's ratio elastography and poroelastography: II</atitle><jtitle>Physics in medicine & biology</jtitle><addtitle>Phys Med Biol</addtitle><date>2007-03-07</date><risdate>2007</risdate><volume>52</volume><issue>5</issue><spage>1321</spage><epage>1333</epage><pages>1321-1333</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><notes>ObjectType-Article-1</notes><notes>SourceType-Scholarly Journals-1</notes><notes>ObjectType-Feature-2</notes><notes>content type line 23</notes><abstract>Poroelastography is a novel elastographic technique for imaging the time variation of the mechanical behaviour of poroelastic materials. Poroelastograms are generated as a series of time-sequenced effective Poisson's ratio (EPR) elastograms, obtained from the imaged material under sustained compression. In the companion report (Righetti et al 2007 Phys. Med. Biol. 52 1303), we investigated image quality of EPR elastography starting from a theoretical analysis of the performance limitations of axial strain elastography and lateral strain elastography. In this report, we extend this analysis to poroelastography. The theoretical analysis reported in these two companion papers allows understanding the performance limitations of these novel techniques and identifying the fundamental parameters that control their signal-to-noise ratio, contrast-to-noise ratio and resolution. The results of these studies also indicate that EPR elastograms and poroelastograms of reasonable image quality can be generated in practical applications that may be of clinical interest provided that advanced elastographic techniques in combination with other commonly employed imaging methods to increase signal-to-noise and contrast-to-noise ratios are used.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>17301457</pmid><doi>10.1088/0031-9155/52/5/008</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0031-9155 |
ispartof | Physics in medicine & biology, 2007-03, Vol.52 (5), p.1321-1333 |
issn | 0031-9155 1361-6560 |
language | eng |
recordid | cdi_proquest_miscellaneous_69010042 |
source | Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List) |
subjects | Algorithms Computer Simulation Elasticity Image Enhancement - methods Image Interpretation, Computer-Assisted - methods Models, Biological Porosity Reproducibility of Results Sensitivity and Specificity Stress, Mechanical Ultrasonography - methods |
title | Assessing image quality in effective Poisson's ratio elastography and poroelastography: II |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-09-23T06%3A35%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessing%20image%20quality%20in%20effective%20Poisson's%20ratio%20elastography%20and%20poroelastography:%20II&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Righetti,%20Raffaella&rft.date=2007-03-07&rft.volume=52&rft.issue=5&rft.spage=1321&rft.epage=1333&rft.pages=1321-1333&rft.issn=0031-9155&rft.eissn=1361-6560&rft_id=info:doi/10.1088/0031-9155/52/5/008&rft_dat=%3Cproquest_pubme%3E69010042%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c373t-5218199a148a4e081e0c3dccd7188b102fb4cff00c33800f700a65240fe4a95a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=69010042&rft_id=info:pmid/17301457&rfr_iscdi=true |