Loading…

User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets

Abstract The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this...

Full description

Saved in:
Bibliographic Details
Published in:Journal of chromatographic science 2017-11, Vol.55 (10), p.979-988
Main Authors: Koppala, Srinivasarao, Ranga Reddy, V, Anireddy, Jaya Shree
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223
cites cdi_FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223
container_end_page 988
container_issue 10
container_start_page 979
container_title Journal of chromatographic science
container_volume 55
creator Koppala, Srinivasarao
Ranga Reddy, V
Anireddy, Jaya Shree
description Abstract The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.
doi_str_mv 10.1093/chromsci/bmx060
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1948759756</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/chromsci/bmx060</oup_id><sourcerecordid>1948759756</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223</originalsourceid><addsrcrecordid>eNqFkM9PwyAYhonRuDk9ezMcjUldoaO0RzN_bMmMHtR4ayh8zTC0VKBGz_7jdtYZb56A73veN-RB6JjE5yTOk6lcO1t7qadl_R6n8Q4ak3zGIprkz7toHMeURHmashE68P5l8yQZ20cjmuUZo5yO0eejBxddOw2NMh94cb-a41sIa6vwJbyBsW0NTcCiUfhJGK1E0LbBlXX9OoCrdTNMbIWvGmFE67TBt8KACPCdWgaPl3XbOR00eKybP9yDKA0Ef4j2KmE8HP2cE_R4ffUwX0Sru5vl_GIVyYQnIZIzQqRUJOOCpllMMiUSqgidlbyaSd7fVcl4mQInlEOVMtFrYKJK8qxSgtJkgk6H3tbZ1w58KGrtJRgjGrCdL3p1GWc5Z2mPTgdUOuu9g6roP1wL91GQuNiYL7bmi8F8nzj5Ke_KGtQvv1XdA2cDYLv237Yv7V6SXA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1948759756</pqid></control><display><type>article</type><title>User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets</title><source>Oxford Journals Online</source><creator>Koppala, Srinivasarao ; Ranga Reddy, V ; Anireddy, Jaya Shree</creator><creatorcontrib>Koppala, Srinivasarao ; Ranga Reddy, V ; Anireddy, Jaya Shree</creatorcontrib><description>Abstract The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.</description><identifier>ISSN: 0021-9665</identifier><identifier>EISSN: 1945-239X</identifier><identifier>DOI: 10.1093/chromsci/bmx060</identifier><identifier>PMID: 28985272</identifier><language>eng</language><publisher>United States: Oxford University Press</publisher><ispartof>Journal of chromatographic science, 2017-11, Vol.55 (10), p.979-988</ispartof><rights>The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com 2017</rights><rights>The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223</citedby><cites>FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,786,790,1591,27957,27958</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28985272$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Koppala, Srinivasarao</creatorcontrib><creatorcontrib>Ranga Reddy, V</creatorcontrib><creatorcontrib>Anireddy, Jaya Shree</creatorcontrib><title>User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets</title><title>Journal of chromatographic science</title><addtitle>J Chromatogr Sci</addtitle><description>Abstract The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.</description><issn>0021-9665</issn><issn>1945-239X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqFkM9PwyAYhonRuDk9ezMcjUldoaO0RzN_bMmMHtR4ayh8zTC0VKBGz_7jdtYZb56A73veN-RB6JjE5yTOk6lcO1t7qadl_R6n8Q4ak3zGIprkz7toHMeURHmashE68P5l8yQZ20cjmuUZo5yO0eejBxddOw2NMh94cb-a41sIa6vwJbyBsW0NTcCiUfhJGK1E0LbBlXX9OoCrdTNMbIWvGmFE67TBt8KACPCdWgaPl3XbOR00eKybP9yDKA0Ef4j2KmE8HP2cE_R4ffUwX0Sru5vl_GIVyYQnIZIzQqRUJOOCpllMMiUSqgidlbyaSd7fVcl4mQInlEOVMtFrYKJK8qxSgtJkgk6H3tbZ1w58KGrtJRgjGrCdL3p1GWc5Z2mPTgdUOuu9g6roP1wL91GQuNiYL7bmi8F8nzj5Ke_KGtQvv1XdA2cDYLv237Yv7V6SXA</recordid><startdate>20171101</startdate><enddate>20171101</enddate><creator>Koppala, Srinivasarao</creator><creator>Ranga Reddy, V</creator><creator>Anireddy, Jaya Shree</creator><general>Oxford University Press</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20171101</creationdate><title>User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets</title><author>Koppala, Srinivasarao ; Ranga Reddy, V ; Anireddy, Jaya Shree</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Koppala, Srinivasarao</creatorcontrib><creatorcontrib>Ranga Reddy, V</creatorcontrib><creatorcontrib>Anireddy, Jaya Shree</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatographic science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Koppala, Srinivasarao</au><au>Ranga Reddy, V</au><au>Anireddy, Jaya Shree</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets</atitle><jtitle>Journal of chromatographic science</jtitle><addtitle>J Chromatogr Sci</addtitle><date>2017-11-01</date><risdate>2017</risdate><volume>55</volume><issue>10</issue><spage>979</spage><epage>988</epage><pages>979-988</pages><issn>0021-9665</issn><eissn>1945-239X</eissn><notes>ObjectType-Article-1</notes><notes>SourceType-Scholarly Journals-1</notes><notes>ObjectType-Feature-2</notes><notes>content type line 23</notes><abstract>Abstract The official method for the determination of Enalapril Maleate and its related substances in European Pharmacopoeia (EP) is a gradient liquid chromatographic method. The method used styrene–divinylbenzene copolymer column, mobile phase buffer pH 6.8 and column oven temperature 70°C. In this method, the separation between main component Enalapril and Ph. Eur. Imp-A was not completed hence the achieving system suitability requirement is a tough task and it requires quite often adjustment in chromatographic parameters. Moreover, column oven temperature 70°C is not user friendly to HPLC instruments and users. In this study, several changes were introduced to the method in order to improve the separation, peak shapes and to overcome the column oven temperature. A new user-friendly stability-indicating RP-HPLC method was developed for Enalapril related substances analysis. The developed method uses a ZORBAX Eclipse XDB-C18 column with column oven temperature at 55°C and mobile phase containing acetonitrile and a phosphate buffer at pH 3.0. The method is capable of separating all the known impurities with resolution more than 3.5, which is much better than that obtained with the existing monograph methods. The optimized method was validated and demonstrated to have acceptable specificity, sensitivity, linearity, accuracy, precision, robustness, solution stability and equivalency to the EP method. The developed method proved to be applicable to a wide number of C18 reversed-phase columns. In addition, the Enalapril assay method also presented with 20 min run time.</abstract><cop>United States</cop><pub>Oxford University Press</pub><pmid>28985272</pmid><doi>10.1093/chromsci/bmx060</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-9665
ispartof Journal of chromatographic science, 2017-11, Vol.55 (10), p.979-988
issn 0021-9665
1945-239X
language eng
recordid cdi_proquest_miscellaneous_1948759756
source Oxford Journals Online
title User-Friendly HPLC Method Development and Validation for Determination of Enalapril Maleate and Its Impurities in Enalapril Tablets
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-09-22T15%3A19%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=User-Friendly%20HPLC%20Method%20Development%20and%20Validation%20for%20Determination%20of%20Enalapril%20Maleate%20and%20Its%20Impurities%20in%20Enalapril%20Tablets&rft.jtitle=Journal%20of%20chromatographic%20science&rft.au=Koppala,%20Srinivasarao&rft.date=2017-11-01&rft.volume=55&rft.issue=10&rft.spage=979&rft.epage=988&rft.pages=979-988&rft.issn=0021-9665&rft.eissn=1945-239X&rft_id=info:doi/10.1093/chromsci/bmx060&rft_dat=%3Cproquest_cross%3E1948759756%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c373t-c411ccd187a268018da32d124b7f4c732ddb57b6e7127ef65a2395af398fda223%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1948759756&rft_id=info:pmid/28985272&rft_oup_id=10.1093/chromsci/bmx060&rfr_iscdi=true