We tested the hypothesis that polarization sensitive optical and terahertz imaging may be combined for accurate nonmelanoma skin cancer (NMSC) delineation. Nine NMSC specimens were imaged. 513 μm and 440 nm wavelengths were used for terahertz and optical imaging, respectively. Histopathology was pro...

Full description

Saved in:
Bibliographic Details
Published in:Journal of biophotonics 2014-05, Vol.7 (5), p.295-303
Main Authors: Joseph, Cecil S., Patel, Rakesh, Neel, Victor A., Giles, Robert H., Yaroslavsky, Anna N.
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We tested the hypothesis that polarization sensitive optical and terahertz imaging may be combined for accurate nonmelanoma skin cancer (NMSC) delineation. Nine NMSC specimens were imaged. 513 μm and 440 nm wavelengths were used for terahertz and optical imaging, respectively. Histopathology was processed for evaluation. Terahertz reflectance of NMSC was quantified. Our results demonstrate that cross‐polarized terahertz images correctly identified location of the tumours, whereas cross‐polarized and polarization difference optical images accurately presented morphological features. Cross‐polarized terahertz images exhibited lower reflectivity values in cancer as compared to normal tissue. Combination of optical and terahertz imaging shows promise for intraoperative delineation of NMSC (© 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)