Loading…

The Effect of Soil-Structure Interaction on Vibration Reliability of Transmission Line

Since the main material of the plug-in foundation transmission tower legs is directly connected to the foundation, the traditional reliability calculation method is no longer accurate. For this reason, this paper considers the soil-structure interaction between the foundation soil and the tower legs...

Full description

Saved in:
Bibliographic Details
Published in:IEEE access 2022, Vol.10, p.20852-20859
Main Authors: Lin, Zhi-Jun, Li, Xiao-Bin, Zhen, Zhi-Ming, Guan, Hua-Shen, Liang, Zu-Hong
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c408t-49c9b7e9603792b2e1c0854f786c979d1af2e5437224d6e2a2a3ca0463b6aa0f3
cites cdi_FETCH-LOGICAL-c408t-49c9b7e9603792b2e1c0854f786c979d1af2e5437224d6e2a2a3ca0463b6aa0f3
container_end_page 20859
container_issue
container_start_page 20852
container_title IEEE access
container_volume 10
creator Lin, Zhi-Jun
Li, Xiao-Bin
Zhen, Zhi-Ming
Guan, Hua-Shen
Liang, Zu-Hong
description Since the main material of the plug-in foundation transmission tower legs is directly connected to the foundation, the traditional reliability calculation method is no longer accurate. For this reason, this paper considers the soil-structure interaction between the foundation soil and the tower legs, replaces the upper limit of the natural circular frequency and frequency ratio of the original iron tower with the corresponding value after considering the SSI (Soil-Structure Interaction), and proposes a SSI-based insertion Analysis method of vibration reliability of type foundation iron tower. First, perform modal analysis to obtain the natural circular frequency of the tower considering SSI; then, according to the external load of the tower under the icing of the wire and the vibration displacement equation of the tower considering SSI, the expression of the comprehensive amplitude amplification factor of the tower is derived, and then the consideration is obtained. The upper limit value of the frequency ratio of SSI and the functional function; finally combined with the normal distribution to solve the problem, the vibration reliability of the plug-in foundation tower considering SSI is obtained. The proposed method has been applied in the analysis of a galloping accident on a line in Guangdong Province. The maximum reliability of the damaged 6-base plug-in foundation tower obtained by this method is 0.9713, which is less than the target reliability of 0.9993.
doi_str_mv 10.1109/ACCESS.2022.3153344
format article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_ieee_primary_9720279</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>9720279</ieee_id><doaj_id>oai_doaj_org_article_f91e7b04905343f1950a6fcfb1e22fc3</doaj_id><sourcerecordid>2635046488</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-49c9b7e9603792b2e1c0854f786c979d1af2e5437224d6e2a2a3ca0463b6aa0f3</originalsourceid><addsrcrecordid>eNpNUUtLAzEQXkRBqf4CLwuet-a1yeZYStVCQbDVa8imE03ZbmqSHvrvTbulOARmMvkega8oHjEaY4zk82Q6nS2XY4IIGVNcU8rYVXFHMJcVrSm__jffFg8xblCuJq9qcVd8rX6gnFkLJpXelkvvumqZwt6kfYBy3icI2iTn-zKfL9cGfbp8QOd06zqXDkfaKug-bl2Mx7eF6-G-uLG6i_Bw7qPi82W2mr5Vi_fX-XSyqAxDTaqYNLIVIDmiQpKWADaoqZkVDTdSyDXWlkDNqCCErTkQTTQ1GjFOW641snRUzAfdtdcbtQtuq8NBee3UaeHDt9IhOdOBshKDaBGTqKaMWixrpLk1tsVAiDU0az0NWrvgf_cQk9r4fejz9xXhtM6urGkyig4oE3yMAezFFSN1zEMNeahjHuqcR2Y9DiwHABeGFBkkJP0DcJKFmw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2635046488</pqid></control><display><type>article</type><title>The Effect of Soil-Structure Interaction on Vibration Reliability of Transmission Line</title><source>IEEE Open Access Journals</source><creator>Lin, Zhi-Jun ; Li, Xiao-Bin ; Zhen, Zhi-Ming ; Guan, Hua-Shen ; Liang, Zu-Hong</creator><creatorcontrib>Lin, Zhi-Jun ; Li, Xiao-Bin ; Zhen, Zhi-Ming ; Guan, Hua-Shen ; Liang, Zu-Hong</creatorcontrib><description>Since the main material of the plug-in foundation transmission tower legs is directly connected to the foundation, the traditional reliability calculation method is no longer accurate. For this reason, this paper considers the soil-structure interaction between the foundation soil and the tower legs, replaces the upper limit of the natural circular frequency and frequency ratio of the original iron tower with the corresponding value after considering the SSI (Soil-Structure Interaction), and proposes a SSI-based insertion Analysis method of vibration reliability of type foundation iron tower. First, perform modal analysis to obtain the natural circular frequency of the tower considering SSI; then, according to the external load of the tower under the icing of the wire and the vibration displacement equation of the tower considering SSI, the expression of the comprehensive amplitude amplification factor of the tower is derived, and then the consideration is obtained. The upper limit value of the frequency ratio of SSI and the functional function; finally combined with the normal distribution to solve the problem, the vibration reliability of the plug-in foundation tower considering SSI is obtained. The proposed method has been applied in the analysis of a galloping accident on a line in Guangdong Province. The maximum reliability of the damaged 6-base plug-in foundation tower obtained by this method is 0.9713, which is less than the target reliability of 0.9993.</description><identifier>ISSN: 2169-3536</identifier><identifier>EISSN: 2169-3536</identifier><identifier>DOI: 10.1109/ACCESS.2022.3153344</identifier><identifier>CODEN: IAECCG</identifier><language>eng</language><publisher>Piscataway: IEEE</publisher><subject>Force ; Ice-coated dancing ; Iron ; Modal analysis ; natural circular frequency ; Normal distribution ; Plugs ; Poles and towers ; Reliability ; Reliability analysis ; Soil ; Soil-structure interaction ; SSI effect ; Transmission lines ; Transmission towers ; Vibration analysis ; vibration reliability ; Vibrations ; Wires</subject><ispartof>IEEE access, 2022, Vol.10, p.20852-20859</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2022</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-49c9b7e9603792b2e1c0854f786c979d1af2e5437224d6e2a2a3ca0463b6aa0f3</citedby><cites>FETCH-LOGICAL-c408t-49c9b7e9603792b2e1c0854f786c979d1af2e5437224d6e2a2a3ca0463b6aa0f3</cites><orcidid>0000-0002-9647-394X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/9720279$$EHTML$$P50$$Gieee$$Hfree_for_read</linktohtml><link.rule.ids>315,786,790,4043,27666,27956,27957,27958,55284</link.rule.ids></links><search><creatorcontrib>Lin, Zhi-Jun</creatorcontrib><creatorcontrib>Li, Xiao-Bin</creatorcontrib><creatorcontrib>Zhen, Zhi-Ming</creatorcontrib><creatorcontrib>Guan, Hua-Shen</creatorcontrib><creatorcontrib>Liang, Zu-Hong</creatorcontrib><title>The Effect of Soil-Structure Interaction on Vibration Reliability of Transmission Line</title><title>IEEE access</title><addtitle>Access</addtitle><description>Since the main material of the plug-in foundation transmission tower legs is directly connected to the foundation, the traditional reliability calculation method is no longer accurate. For this reason, this paper considers the soil-structure interaction between the foundation soil and the tower legs, replaces the upper limit of the natural circular frequency and frequency ratio of the original iron tower with the corresponding value after considering the SSI (Soil-Structure Interaction), and proposes a SSI-based insertion Analysis method of vibration reliability of type foundation iron tower. First, perform modal analysis to obtain the natural circular frequency of the tower considering SSI; then, according to the external load of the tower under the icing of the wire and the vibration displacement equation of the tower considering SSI, the expression of the comprehensive amplitude amplification factor of the tower is derived, and then the consideration is obtained. The upper limit value of the frequency ratio of SSI and the functional function; finally combined with the normal distribution to solve the problem, the vibration reliability of the plug-in foundation tower considering SSI is obtained. The proposed method has been applied in the analysis of a galloping accident on a line in Guangdong Province. The maximum reliability of the damaged 6-base plug-in foundation tower obtained by this method is 0.9713, which is less than the target reliability of 0.9993.</description><subject>Force</subject><subject>Ice-coated dancing</subject><subject>Iron</subject><subject>Modal analysis</subject><subject>natural circular frequency</subject><subject>Normal distribution</subject><subject>Plugs</subject><subject>Poles and towers</subject><subject>Reliability</subject><subject>Reliability analysis</subject><subject>Soil</subject><subject>Soil-structure interaction</subject><subject>SSI effect</subject><subject>Transmission lines</subject><subject>Transmission towers</subject><subject>Vibration analysis</subject><subject>vibration reliability</subject><subject>Vibrations</subject><subject>Wires</subject><issn>2169-3536</issn><issn>2169-3536</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>ESBDL</sourceid><sourceid>DOA</sourceid><recordid>eNpNUUtLAzEQXkRBqf4CLwuet-a1yeZYStVCQbDVa8imE03ZbmqSHvrvTbulOARmMvkega8oHjEaY4zk82Q6nS2XY4IIGVNcU8rYVXFHMJcVrSm__jffFg8xblCuJq9qcVd8rX6gnFkLJpXelkvvumqZwt6kfYBy3icI2iTn-zKfL9cGfbp8QOd06zqXDkfaKug-bl2Mx7eF6-G-uLG6i_Bw7qPi82W2mr5Vi_fX-XSyqAxDTaqYNLIVIDmiQpKWADaoqZkVDTdSyDXWlkDNqCCErTkQTTQ1GjFOW641snRUzAfdtdcbtQtuq8NBee3UaeHDt9IhOdOBshKDaBGTqKaMWixrpLk1tsVAiDU0az0NWrvgf_cQk9r4fejz9xXhtM6urGkyig4oE3yMAezFFSN1zEMNeahjHuqcR2Y9DiwHABeGFBkkJP0DcJKFmw</recordid><startdate>2022</startdate><enddate>2022</enddate><creator>Lin, Zhi-Jun</creator><creator>Li, Xiao-Bin</creator><creator>Zhen, Zhi-Ming</creator><creator>Guan, Hua-Shen</creator><creator>Liang, Zu-Hong</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>ESBDL</scope><scope>RIA</scope><scope>RIE</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SC</scope><scope>7SP</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-9647-394X</orcidid></search><sort><creationdate>2022</creationdate><title>The Effect of Soil-Structure Interaction on Vibration Reliability of Transmission Line</title><author>Lin, Zhi-Jun ; Li, Xiao-Bin ; Zhen, Zhi-Ming ; Guan, Hua-Shen ; Liang, Zu-Hong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-49c9b7e9603792b2e1c0854f786c979d1af2e5437224d6e2a2a3ca0463b6aa0f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Force</topic><topic>Ice-coated dancing</topic><topic>Iron</topic><topic>Modal analysis</topic><topic>natural circular frequency</topic><topic>Normal distribution</topic><topic>Plugs</topic><topic>Poles and towers</topic><topic>Reliability</topic><topic>Reliability analysis</topic><topic>Soil</topic><topic>Soil-structure interaction</topic><topic>SSI effect</topic><topic>Transmission lines</topic><topic>Transmission towers</topic><topic>Vibration analysis</topic><topic>vibration reliability</topic><topic>Vibrations</topic><topic>Wires</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lin, Zhi-Jun</creatorcontrib><creatorcontrib>Li, Xiao-Bin</creatorcontrib><creatorcontrib>Zhen, Zhi-Ming</creatorcontrib><creatorcontrib>Guan, Hua-Shen</creatorcontrib><creatorcontrib>Liang, Zu-Hong</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE Open Access Journals</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998–Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>CrossRef</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>IEEE access</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lin, Zhi-Jun</au><au>Li, Xiao-Bin</au><au>Zhen, Zhi-Ming</au><au>Guan, Hua-Shen</au><au>Liang, Zu-Hong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The Effect of Soil-Structure Interaction on Vibration Reliability of Transmission Line</atitle><jtitle>IEEE access</jtitle><stitle>Access</stitle><date>2022</date><risdate>2022</risdate><volume>10</volume><spage>20852</spage><epage>20859</epage><pages>20852-20859</pages><issn>2169-3536</issn><eissn>2169-3536</eissn><coden>IAECCG</coden><abstract>Since the main material of the plug-in foundation transmission tower legs is directly connected to the foundation, the traditional reliability calculation method is no longer accurate. For this reason, this paper considers the soil-structure interaction between the foundation soil and the tower legs, replaces the upper limit of the natural circular frequency and frequency ratio of the original iron tower with the corresponding value after considering the SSI (Soil-Structure Interaction), and proposes a SSI-based insertion Analysis method of vibration reliability of type foundation iron tower. First, perform modal analysis to obtain the natural circular frequency of the tower considering SSI; then, according to the external load of the tower under the icing of the wire and the vibration displacement equation of the tower considering SSI, the expression of the comprehensive amplitude amplification factor of the tower is derived, and then the consideration is obtained. The upper limit value of the frequency ratio of SSI and the functional function; finally combined with the normal distribution to solve the problem, the vibration reliability of the plug-in foundation tower considering SSI is obtained. The proposed method has been applied in the analysis of a galloping accident on a line in Guangdong Province. The maximum reliability of the damaged 6-base plug-in foundation tower obtained by this method is 0.9713, which is less than the target reliability of 0.9993.</abstract><cop>Piscataway</cop><pub>IEEE</pub><doi>10.1109/ACCESS.2022.3153344</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-9647-394X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2169-3536
ispartof IEEE access, 2022, Vol.10, p.20852-20859
issn 2169-3536
2169-3536
language eng
recordid cdi_ieee_primary_9720279
source IEEE Open Access Journals
subjects Force
Ice-coated dancing
Iron
Modal analysis
natural circular frequency
Normal distribution
Plugs
Poles and towers
Reliability
Reliability analysis
Soil
Soil-structure interaction
SSI effect
Transmission lines
Transmission towers
Vibration analysis
vibration reliability
Vibrations
Wires
title The Effect of Soil-Structure Interaction on Vibration Reliability of Transmission Line
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-09-22T17%3A26%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20Effect%20of%20Soil-Structure%20Interaction%20on%20Vibration%20Reliability%20of%20Transmission%20Line&rft.jtitle=IEEE%20access&rft.au=Lin,%20Zhi-Jun&rft.date=2022&rft.volume=10&rft.spage=20852&rft.epage=20859&rft.pages=20852-20859&rft.issn=2169-3536&rft.eissn=2169-3536&rft.coden=IAECCG&rft_id=info:doi/10.1109/ACCESS.2022.3153344&rft_dat=%3Cproquest_ieee_%3E2635046488%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c408t-49c9b7e9603792b2e1c0854f786c979d1af2e5437224d6e2a2a3ca0463b6aa0f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2635046488&rft_id=info:pmid/&rft_ieee_id=9720279&rfr_iscdi=true