Loading…

X-ray diagnostics for plasma temperature measurement on shiva star

Summary form only given. Arrays of Si PIN diodes are fielded on radiation producing experiments on the Shiva Star pulsed power generator at AFRL's Directed Energy Directorate. This work is a continuation of earlier work done on Shiva Star. Each diode is filtered to respond to a part of the band...

Full description

Saved in:
Bibliographic Details
Main Authors: White, William M, Degnan, James H, Wood, Haynes R, Domonkos, Matthew T, Coffey, Sean K, Camacho, J Frank, Grabowski, T Chris
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 1
container_issue
container_start_page 1
container_title
container_volume
creator White, William M
Degnan, James H
Wood, Haynes R
Domonkos, Matthew T
Coffey, Sean K
Camacho, J Frank
Grabowski, T Chris
description Summary form only given. Arrays of Si PIN diodes are fielded on radiation producing experiments on the Shiva Star pulsed power generator at AFRL's Directed Energy Directorate. This work is a continuation of earlier work done on Shiva Star. Each diode is filtered to respond to a part of the band of interest and the signals are then deconvolved to generate the radiation spectrum as a function of time. The plasma temperature may be inferred from this method, assuming Bremsstrahlung radiative processes, and impurities may be detected by a departure from the mean temperature.This diagnostic may be extended to other types and numbers of detectors.
doi_str_mv 10.1109/PLASMA.2010.5534200
format conference_proceeding
fullrecord <record><control><sourceid>ieee_CHZPO</sourceid><recordid>TN_cdi_ieee_primary_5534200</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>5534200</ieee_id><sourcerecordid>5534200</sourcerecordid><originalsourceid>FETCH-ieee_primary_55342003</originalsourceid><addsrcrecordid>eNp9js1qAjEUhW__wMHOE7jJC4y9k0kaZ6ml4qKCoAt3cmmvbYqZGXJTwbdvFm666dl8cD44HIBJjdO6xvZp8zbfrudTjbmwtjEa8QbK1s1qo42xxllzC4W27rlyGmd3f5xx91Cga7BqczGCUuQbc4zNM66Axb6KdFEfnj67XpJ_F3XsoxpOJIFU4jBwpPQTWQUmyQzcJdV3Sr78mZQkio_wcKSTcHnlGCbL193LqvLMfBiiDxQvh-vz5n_7CyyOQYI</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>X-ray diagnostics for plasma temperature measurement on shiva star</title><source>IEEE Xplore All Conference Series</source><creator>White, William M ; Degnan, James H ; Wood, Haynes R ; Domonkos, Matthew T ; Coffey, Sean K ; Camacho, J Frank ; Grabowski, T Chris</creator><creatorcontrib>White, William M ; Degnan, James H ; Wood, Haynes R ; Domonkos, Matthew T ; Coffey, Sean K ; Camacho, J Frank ; Grabowski, T Chris</creatorcontrib><description>Summary form only given. Arrays of Si PIN diodes are fielded on radiation producing experiments on the Shiva Star pulsed power generator at AFRL's Directed Energy Directorate. This work is a continuation of earlier work done on Shiva Star. Each diode is filtered to respond to a part of the band of interest and the signals are then deconvolved to generate the radiation spectrum as a function of time. The plasma temperature may be inferred from this method, assuming Bremsstrahlung radiative processes, and impurities may be detected by a departure from the mean temperature.This diagnostic may be extended to other types and numbers of detectors.</description><identifier>ISSN: 0730-9244</identifier><identifier>ISBN: 9781424454747</identifier><identifier>ISBN: 1424454743</identifier><identifier>EISSN: 2576-7208</identifier><identifier>EISBN: 9781424454754</identifier><identifier>EISBN: 1424454751</identifier><identifier>EISBN: 142445476X</identifier><identifier>EISBN: 9781424454761</identifier><identifier>DOI: 10.1109/PLASMA.2010.5534200</identifier><language>eng</language><publisher>IEEE</publisher><subject>Energy measurement ; Force measurement ; Laboratories ; Plasma measurements ; Plasma temperature ; Power generation ; Power measurement ; Pulse generation ; Pulse measurements ; Temperature measurement</subject><ispartof>2010 Abstracts IEEE International Conference on Plasma Science, 2010, p.1-1</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/5534200$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>310,311,786,790,795,796,2071,27958,54906,55271,55283</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/5534200$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>White, William M</creatorcontrib><creatorcontrib>Degnan, James H</creatorcontrib><creatorcontrib>Wood, Haynes R</creatorcontrib><creatorcontrib>Domonkos, Matthew T</creatorcontrib><creatorcontrib>Coffey, Sean K</creatorcontrib><creatorcontrib>Camacho, J Frank</creatorcontrib><creatorcontrib>Grabowski, T Chris</creatorcontrib><title>X-ray diagnostics for plasma temperature measurement on shiva star</title><title>2010 Abstracts IEEE International Conference on Plasma Science</title><addtitle>PLASMA</addtitle><description>Summary form only given. Arrays of Si PIN diodes are fielded on radiation producing experiments on the Shiva Star pulsed power generator at AFRL's Directed Energy Directorate. This work is a continuation of earlier work done on Shiva Star. Each diode is filtered to respond to a part of the band of interest and the signals are then deconvolved to generate the radiation spectrum as a function of time. The plasma temperature may be inferred from this method, assuming Bremsstrahlung radiative processes, and impurities may be detected by a departure from the mean temperature.This diagnostic may be extended to other types and numbers of detectors.</description><subject>Energy measurement</subject><subject>Force measurement</subject><subject>Laboratories</subject><subject>Plasma measurements</subject><subject>Plasma temperature</subject><subject>Power generation</subject><subject>Power measurement</subject><subject>Pulse generation</subject><subject>Pulse measurements</subject><subject>Temperature measurement</subject><issn>0730-9244</issn><issn>2576-7208</issn><isbn>9781424454747</isbn><isbn>1424454743</isbn><isbn>9781424454754</isbn><isbn>1424454751</isbn><isbn>142445476X</isbn><isbn>9781424454761</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2010</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><recordid>eNp9js1qAjEUhW__wMHOE7jJC4y9k0kaZ6ml4qKCoAt3cmmvbYqZGXJTwbdvFm666dl8cD44HIBJjdO6xvZp8zbfrudTjbmwtjEa8QbK1s1qo42xxllzC4W27rlyGmd3f5xx91Cga7BqczGCUuQbc4zNM66Axb6KdFEfnj67XpJ_F3XsoxpOJIFU4jBwpPQTWQUmyQzcJdV3Sr78mZQkio_wcKSTcHnlGCbL193LqvLMfBiiDxQvh-vz5n_7CyyOQYI</recordid><startdate>201006</startdate><enddate>201006</enddate><creator>White, William M</creator><creator>Degnan, James H</creator><creator>Wood, Haynes R</creator><creator>Domonkos, Matthew T</creator><creator>Coffey, Sean K</creator><creator>Camacho, J Frank</creator><creator>Grabowski, T Chris</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>201006</creationdate><title>X-ray diagnostics for plasma temperature measurement on shiva star</title><author>White, William M ; Degnan, James H ; Wood, Haynes R ; Domonkos, Matthew T ; Coffey, Sean K ; Camacho, J Frank ; Grabowski, T Chris</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ieee_primary_55342003</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Energy measurement</topic><topic>Force measurement</topic><topic>Laboratories</topic><topic>Plasma measurements</topic><topic>Plasma temperature</topic><topic>Power generation</topic><topic>Power measurement</topic><topic>Pulse generation</topic><topic>Pulse measurements</topic><topic>Temperature measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>White, William M</creatorcontrib><creatorcontrib>Degnan, James H</creatorcontrib><creatorcontrib>Wood, Haynes R</creatorcontrib><creatorcontrib>Domonkos, Matthew T</creatorcontrib><creatorcontrib>Coffey, Sean K</creatorcontrib><creatorcontrib>Camacho, J Frank</creatorcontrib><creatorcontrib>Grabowski, T Chris</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Xplore</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>White, William M</au><au>Degnan, James H</au><au>Wood, Haynes R</au><au>Domonkos, Matthew T</au><au>Coffey, Sean K</au><au>Camacho, J Frank</au><au>Grabowski, T Chris</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>X-ray diagnostics for plasma temperature measurement on shiva star</atitle><btitle>2010 Abstracts IEEE International Conference on Plasma Science</btitle><stitle>PLASMA</stitle><date>2010-06</date><risdate>2010</risdate><spage>1</spage><epage>1</epage><pages>1-1</pages><issn>0730-9244</issn><eissn>2576-7208</eissn><isbn>9781424454747</isbn><isbn>1424454743</isbn><eisbn>9781424454754</eisbn><eisbn>1424454751</eisbn><eisbn>142445476X</eisbn><eisbn>9781424454761</eisbn><abstract>Summary form only given. Arrays of Si PIN diodes are fielded on radiation producing experiments on the Shiva Star pulsed power generator at AFRL's Directed Energy Directorate. This work is a continuation of earlier work done on Shiva Star. Each diode is filtered to respond to a part of the band of interest and the signals are then deconvolved to generate the radiation spectrum as a function of time. The plasma temperature may be inferred from this method, assuming Bremsstrahlung radiative processes, and impurities may be detected by a departure from the mean temperature.This diagnostic may be extended to other types and numbers of detectors.</abstract><pub>IEEE</pub><doi>10.1109/PLASMA.2010.5534200</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0730-9244
ispartof 2010 Abstracts IEEE International Conference on Plasma Science, 2010, p.1-1
issn 0730-9244
2576-7208
language eng
recordid cdi_ieee_primary_5534200
source IEEE Xplore All Conference Series
subjects Energy measurement
Force measurement
Laboratories
Plasma measurements
Plasma temperature
Power generation
Power measurement
Pulse generation
Pulse measurements
Temperature measurement
title X-ray diagnostics for plasma temperature measurement on shiva star
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-09-22T15%3A37%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_CHZPO&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=X-ray%20diagnostics%20for%20plasma%20temperature%20measurement%20on%20shiva%20star&rft.btitle=2010%20Abstracts%20IEEE%20International%20Conference%20on%20Plasma%20Science&rft.au=White,%20William%20M&rft.date=2010-06&rft.spage=1&rft.epage=1&rft.pages=1-1&rft.issn=0730-9244&rft.eissn=2576-7208&rft.isbn=9781424454747&rft.isbn_list=1424454743&rft_id=info:doi/10.1109/PLASMA.2010.5534200&rft.eisbn=9781424454754&rft.eisbn_list=1424454751&rft.eisbn_list=142445476X&rft.eisbn_list=9781424454761&rft_dat=%3Cieee_CHZPO%3E5534200%3C/ieee_CHZPO%3E%3Cgrp_id%3Ecdi_FETCH-ieee_primary_55342003%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=5534200&rfr_iscdi=true