Traveling Wave-Based Fault Location for Gas Insulated Substations

Abstract With the growing demand for solutions to prevent and resolve faults in gas-insulated substations that affect the operation of the electrical system, a fault simulation laboratory for gas-insulated substations was developed to develop solutions for monitoring and locating these faults. The l...

Full description

Saved in:
Bibliographic Details
Published in:Brazilian Archives of Biology and Technology 2024, Vol.67
Main Authors: Marcelo, Diogo Gonzaga, Silva, Clailton Leopoldo da, Martins, Rafael, Castioni, Júlio Cezar Oliveira, Lambert-Torres, Germano, Ribeiro Junior, Ronny Francis, Campos, Mateus Mendes, Areias, Isac Antônio dos Santos, Assunção, Frederico de Oliveira, Silva, Luiz Eduardo Borges da
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c351t-88e417e958e35eec91d45f76d9af1fec2033811c95a62d0f2e7311ec27d18b873
container_end_page
container_issue
container_start_page
container_title Brazilian Archives of Biology and Technology
container_volume 67
creator Marcelo, Diogo Gonzaga
Silva, Clailton Leopoldo da
Martins, Rafael
Castioni, Júlio Cezar Oliveira
Lambert-Torres, Germano
Ribeiro Junior, Ronny Francis
Campos, Mateus Mendes
Areias, Isac Antônio dos Santos
Assunção, Frederico de Oliveira
Silva, Luiz Eduardo Borges da
description Abstract With the growing demand for solutions to prevent and resolve faults in gas-insulated substations that affect the operation of the electrical system, a fault simulation laboratory for gas-insulated substations was developed to develop solutions for monitoring and locating these faults. The laboratory is composed of instruments for a fault location system based on traveling wave theory. The laboratory also has computational programs for fault simulation control and signal acquisition, in addition to having tools to analyze the data. The results were obtained through tests carried out that confirmed the laboratory's ability to simulate the operation of faults in gas-insulated substations, which allowed demonstrating the capacity of the fault location system using the theory of traveling waves.
doi_str_mv 10.1590/1678-4324-2024230514
format article
fullrecord <record><control><sourceid>doaj_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1590_1678_4324_2024230514</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_0ef74f53eb7e4f1fa22531c3a11142fe</doaj_id><sourcerecordid>oai_doaj_org_article_0ef74f53eb7e4f1fa22531c3a11142fe</sourcerecordid><originalsourceid>FETCH-LOGICAL-c351t-88e417e958e35eec91d45f76d9af1fec2033811c95a62d0f2e7311ec27d18b873</originalsourceid><addsrcrecordid>eNpFkM1KAzEUhYMoWKtv4GJeYDQ3P5PMshZbCwUXVlyG28xNmTI2kkwF395pK3V1D-dcvsXH2D3wB9A1f4TK2FJJoUrBhRKSa1AXbHSuL4esoSptDfKa3eS85RxUBWrEJquE39S1u03xMYTyCTM1xQz3XV8so8e-jbsixFTMMReLXd532A8Pb_t17o9jvmVXAbtMd393zN5nz6vpS7l8nS-mk2XppYa-tJYUGKq1JamJfA2N0sFUTY0BAnnBpbQAvtZYiYYHQUYCDL1pwK6tkWO2OHGbiFv3ldpPTD8uYuuORUwbh6lvfUeOUzAqaElrQ2qgoxBagpcIAEoEGljqxPIp5pwonHnA3UGpO7hzB3fuX6n8BRMOaFQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Traveling Wave-Based Fault Location for Gas Insulated Substations</title><source>SciELO Brazil</source><creator>Marcelo, Diogo Gonzaga ; Silva, Clailton Leopoldo da ; Martins, Rafael ; Castioni, Júlio Cezar Oliveira ; Lambert-Torres, Germano ; Ribeiro Junior, Ronny Francis ; Campos, Mateus Mendes ; Areias, Isac Antônio dos Santos ; Assunção, Frederico de Oliveira ; Silva, Luiz Eduardo Borges da</creator><creatorcontrib>Marcelo, Diogo Gonzaga ; Silva, Clailton Leopoldo da ; Martins, Rafael ; Castioni, Júlio Cezar Oliveira ; Lambert-Torres, Germano ; Ribeiro Junior, Ronny Francis ; Campos, Mateus Mendes ; Areias, Isac Antônio dos Santos ; Assunção, Frederico de Oliveira ; Silva, Luiz Eduardo Borges da</creatorcontrib><description>Abstract With the growing demand for solutions to prevent and resolve faults in gas-insulated substations that affect the operation of the electrical system, a fault simulation laboratory for gas-insulated substations was developed to develop solutions for monitoring and locating these faults. The laboratory is composed of instruments for a fault location system based on traveling wave theory. The laboratory also has computational programs for fault simulation control and signal acquisition, in addition to having tools to analyze the data. The results were obtained through tests carried out that confirmed the laboratory's ability to simulate the operation of faults in gas-insulated substations, which allowed demonstrating the capacity of the fault location system using the theory of traveling waves.</description><identifier>ISSN: 1516-8913</identifier><identifier>EISSN: 1678-4324</identifier><identifier>DOI: 10.1590/1678-4324-2024230514</identifier><language>eng</language><publisher>Instituto de Tecnologia do Paraná (Tecpar)</publisher><subject>Fault location ; Gas insulated substations ; Simulation laboratory ; Traveling waves</subject><ispartof>Brazilian Archives of Biology and Technology, 2024, Vol.67</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c351t-88e417e958e35eec91d45f76d9af1fec2033811c95a62d0f2e7311ec27d18b873</cites><orcidid>0000-0003-3789-4696 ; 0000-0002-8654-1048 ; 0000-0002-5304-8628 ; 0000-0003-4562-5285 ; 0000-0003-0244-3553 ; 0000-0002-5832-9402 ; 0000-0002-1144-9247 ; 0000-0001-7840-0352 ; 0000-0003-2298-1017 ; 0000-0002-0776-2978</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,786,790,4043,27956,27957,27958</link.rule.ids></links><search><creatorcontrib>Marcelo, Diogo Gonzaga</creatorcontrib><creatorcontrib>Silva, Clailton Leopoldo da</creatorcontrib><creatorcontrib>Martins, Rafael</creatorcontrib><creatorcontrib>Castioni, Júlio Cezar Oliveira</creatorcontrib><creatorcontrib>Lambert-Torres, Germano</creatorcontrib><creatorcontrib>Ribeiro Junior, Ronny Francis</creatorcontrib><creatorcontrib>Campos, Mateus Mendes</creatorcontrib><creatorcontrib>Areias, Isac Antônio dos Santos</creatorcontrib><creatorcontrib>Assunção, Frederico de Oliveira</creatorcontrib><creatorcontrib>Silva, Luiz Eduardo Borges da</creatorcontrib><title>Traveling Wave-Based Fault Location for Gas Insulated Substations</title><title>Brazilian Archives of Biology and Technology</title><description>Abstract With the growing demand for solutions to prevent and resolve faults in gas-insulated substations that affect the operation of the electrical system, a fault simulation laboratory for gas-insulated substations was developed to develop solutions for monitoring and locating these faults. The laboratory is composed of instruments for a fault location system based on traveling wave theory. The laboratory also has computational programs for fault simulation control and signal acquisition, in addition to having tools to analyze the data. The results were obtained through tests carried out that confirmed the laboratory's ability to simulate the operation of faults in gas-insulated substations, which allowed demonstrating the capacity of the fault location system using the theory of traveling waves.</description><subject>Fault location</subject><subject>Gas insulated substations</subject><subject>Simulation laboratory</subject><subject>Traveling waves</subject><issn>1516-8913</issn><issn>1678-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpFkM1KAzEUhYMoWKtv4GJeYDQ3P5PMshZbCwUXVlyG28xNmTI2kkwF395pK3V1D-dcvsXH2D3wB9A1f4TK2FJJoUrBhRKSa1AXbHSuL4esoSptDfKa3eS85RxUBWrEJquE39S1u03xMYTyCTM1xQz3XV8so8e-jbsixFTMMReLXd532A8Pb_t17o9jvmVXAbtMd393zN5nz6vpS7l8nS-mk2XppYa-tJYUGKq1JamJfA2N0sFUTY0BAnnBpbQAvtZYiYYHQUYCDL1pwK6tkWO2OHGbiFv3ldpPTD8uYuuORUwbh6lvfUeOUzAqaElrQ2qgoxBagpcIAEoEGljqxPIp5pwonHnA3UGpO7hzB3fuX6n8BRMOaFQ</recordid><startdate>2024</startdate><enddate>2024</enddate><creator>Marcelo, Diogo Gonzaga</creator><creator>Silva, Clailton Leopoldo da</creator><creator>Martins, Rafael</creator><creator>Castioni, Júlio Cezar Oliveira</creator><creator>Lambert-Torres, Germano</creator><creator>Ribeiro Junior, Ronny Francis</creator><creator>Campos, Mateus Mendes</creator><creator>Areias, Isac Antônio dos Santos</creator><creator>Assunção, Frederico de Oliveira</creator><creator>Silva, Luiz Eduardo Borges da</creator><general>Instituto de Tecnologia do Paraná (Tecpar)</general><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0003-3789-4696</orcidid><orcidid>https://orcid.org/0000-0002-8654-1048</orcidid><orcidid>https://orcid.org/0000-0002-5304-8628</orcidid><orcidid>https://orcid.org/0000-0003-4562-5285</orcidid><orcidid>https://orcid.org/0000-0003-0244-3553</orcidid><orcidid>https://orcid.org/0000-0002-5832-9402</orcidid><orcidid>https://orcid.org/0000-0002-1144-9247</orcidid><orcidid>https://orcid.org/0000-0001-7840-0352</orcidid><orcidid>https://orcid.org/0000-0003-2298-1017</orcidid><orcidid>https://orcid.org/0000-0002-0776-2978</orcidid></search><sort><creationdate>2024</creationdate><title>Traveling Wave-Based Fault Location for Gas Insulated Substations</title><author>Marcelo, Diogo Gonzaga ; Silva, Clailton Leopoldo da ; Martins, Rafael ; Castioni, Júlio Cezar Oliveira ; Lambert-Torres, Germano ; Ribeiro Junior, Ronny Francis ; Campos, Mateus Mendes ; Areias, Isac Antônio dos Santos ; Assunção, Frederico de Oliveira ; Silva, Luiz Eduardo Borges da</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c351t-88e417e958e35eec91d45f76d9af1fec2033811c95a62d0f2e7311ec27d18b873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Fault location</topic><topic>Gas insulated substations</topic><topic>Simulation laboratory</topic><topic>Traveling waves</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Marcelo, Diogo Gonzaga</creatorcontrib><creatorcontrib>Silva, Clailton Leopoldo da</creatorcontrib><creatorcontrib>Martins, Rafael</creatorcontrib><creatorcontrib>Castioni, Júlio Cezar Oliveira</creatorcontrib><creatorcontrib>Lambert-Torres, Germano</creatorcontrib><creatorcontrib>Ribeiro Junior, Ronny Francis</creatorcontrib><creatorcontrib>Campos, Mateus Mendes</creatorcontrib><creatorcontrib>Areias, Isac Antônio dos Santos</creatorcontrib><creatorcontrib>Assunção, Frederico de Oliveira</creatorcontrib><creatorcontrib>Silva, Luiz Eduardo Borges da</creatorcontrib><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Brazilian Archives of Biology and Technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Marcelo, Diogo Gonzaga</au><au>Silva, Clailton Leopoldo da</au><au>Martins, Rafael</au><au>Castioni, Júlio Cezar Oliveira</au><au>Lambert-Torres, Germano</au><au>Ribeiro Junior, Ronny Francis</au><au>Campos, Mateus Mendes</au><au>Areias, Isac Antônio dos Santos</au><au>Assunção, Frederico de Oliveira</au><au>Silva, Luiz Eduardo Borges da</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Traveling Wave-Based Fault Location for Gas Insulated Substations</atitle><jtitle>Brazilian Archives of Biology and Technology</jtitle><date>2024</date><risdate>2024</risdate><volume>67</volume><issn>1516-8913</issn><eissn>1678-4324</eissn><abstract>Abstract With the growing demand for solutions to prevent and resolve faults in gas-insulated substations that affect the operation of the electrical system, a fault simulation laboratory for gas-insulated substations was developed to develop solutions for monitoring and locating these faults. The laboratory is composed of instruments for a fault location system based on traveling wave theory. The laboratory also has computational programs for fault simulation control and signal acquisition, in addition to having tools to analyze the data. The results were obtained through tests carried out that confirmed the laboratory's ability to simulate the operation of faults in gas-insulated substations, which allowed demonstrating the capacity of the fault location system using the theory of traveling waves.</abstract><pub>Instituto de Tecnologia do Paraná (Tecpar)</pub><doi>10.1590/1678-4324-2024230514</doi><orcidid>https://orcid.org/0000-0003-3789-4696</orcidid><orcidid>https://orcid.org/0000-0002-8654-1048</orcidid><orcidid>https://orcid.org/0000-0002-5304-8628</orcidid><orcidid>https://orcid.org/0000-0003-4562-5285</orcidid><orcidid>https://orcid.org/0000-0003-0244-3553</orcidid><orcidid>https://orcid.org/0000-0002-5832-9402</orcidid><orcidid>https://orcid.org/0000-0002-1144-9247</orcidid><orcidid>https://orcid.org/0000-0001-7840-0352</orcidid><orcidid>https://orcid.org/0000-0003-2298-1017</orcidid><orcidid>https://orcid.org/0000-0002-0776-2978</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1516-8913
ispartof Brazilian Archives of Biology and Technology, 2024, Vol.67
issn 1516-8913
1678-4324
language eng
recordid cdi_crossref_primary_10_1590_1678_4324_2024230514
source SciELO Brazil
subjects Fault location
Gas insulated substations
Simulation laboratory
Traveling waves
title Traveling Wave-Based Fault Location for Gas Insulated Substations
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-09-22T01%3A47%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Traveling%20Wave-Based%20Fault%20Location%20for%20Gas%20Insulated%20Substations&rft.jtitle=Brazilian%20Archives%20of%20Biology%20and%20Technology&rft.au=Marcelo,%20Diogo%20Gonzaga&rft.date=2024&rft.volume=67&rft.issn=1516-8913&rft.eissn=1678-4324&rft_id=info:doi/10.1590/1678-4324-2024230514&rft_dat=%3Cdoaj_cross%3Eoai_doaj_org_article_0ef74f53eb7e4f1fa22531c3a11142fe%3C/doaj_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c351t-88e417e958e35eec91d45f76d9af1fec2033811c95a62d0f2e7311ec27d18b873%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true