Loading…

Effect of vertical strand location on bond performance of prestressing strands cast in lightweight self-consolidating concrete

The high fluidity of lightweight self-consolidating concrete (LWSCC) combined with the tendency for some aggregate particles to collect near the top of the member has the potential to affect bond of prestressing strands with a significant amount of concrete below. Transfer and development length wer...

Full description

Saved in:
Bibliographic Details
Published in:Journal of structural integrity and maintenance 2017-01, Vol.2 (1), p.39-47
Main Authors: Sadhasivam, Kavitha, Bella Canet, Elvira, Wendling, Arthur, Floyd, Royce W.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c240t-8b2969fe0388b27d22445b0449f92348d16d0c13dfc3d50b4bc561b62d93bb443
cites cdi_FETCH-LOGICAL-c240t-8b2969fe0388b27d22445b0449f92348d16d0c13dfc3d50b4bc561b62d93bb443
container_end_page 47
container_issue 1
container_start_page 39
container_title Journal of structural integrity and maintenance
container_volume 2
creator Sadhasivam, Kavitha
Bella Canet, Elvira
Wendling, Arthur
Floyd, Royce W.
description The high fluidity of lightweight self-consolidating concrete (LWSCC) combined with the tendency for some aggregate particles to collect near the top of the member has the potential to affect bond of prestressing strands with a significant amount of concrete below. Transfer and development length were evaluated for rectangular beam specimens cast with LWSCC and normal weight self-consolidating concrete (SCC). Each member was prestressed with a single 13.3 mm prestressing strand and cast with 300 mm of concrete either above or below the prestressing strand. Strand end slip was used to compare prestress transfer behavior, and measured transfer lengths were compared to the ACI and American Association of State Highway and Transportation Officials (AASHTO) equations. Development length was evaluated using flexural tests with a critical section at the code calculated value. The results of the experimental program indicate an increase in transfer length for strands placed near the top of the members cast with SCC. The ACI/AASHTO equation and AASHTO 60d b expression produced reasonable average predictions for transfer length of bottom strand specimens, but underestimated transfer length for top strand specimens. Flexural tests indicated a development length larger than the value predicted using the ACI and AASHTO code equations for specimens with 300 mm of concrete below.
doi_str_mv 10.1080/24705314.2017.1280588
format article
fullrecord <record><control><sourceid>crossref_infor</sourceid><recordid>TN_cdi_crossref_primary_10_1080_24705314_2017_1280588</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1080_24705314_2017_1280588</sourcerecordid><originalsourceid>FETCH-LOGICAL-c240t-8b2969fe0388b27d22445b0449f92348d16d0c13dfc3d50b4bc561b62d93bb443</originalsourceid><addsrcrecordid>eNp9UNtKAzEQDaJgqf0EIT-wNdft7ptSqhYKvuhzyLVG0k1JgqUvfrtZW30UhpkzwzkH5gBwi9Ecow7dEbZAnGI2Jwgv5ph0iHfdBZiM94ZTQi7_MGbXYJbzB0IIt5y1DE_A18o5qwuMDn7aVLyWAeaS5GBgiFoWHwdYS8V62NvkYtrJQduRv0-2Mm3OftieNRlqmQv0Awx--14Oduww2-AaHYccgzfVstLrppMt9gZcORmynZ3nFLw9rl6Xz83m5Wm9fNg0mjBUmk6Rvu2dRbSrcGEIYYwrxFjvekJZZ3BrkMbUOE0NR4opzVusWmJ6qhRjdAr4yVenmHOyTuyT38l0FBiJMUfxm6MYcxTnHKvu_qTzw8_rh5iCEUUeQ0yufqx9FvR_i28Pf3xD</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Effect of vertical strand location on bond performance of prestressing strands cast in lightweight self-consolidating concrete</title><source>Taylor and Francis Science and Technology Collection</source><creator>Sadhasivam, Kavitha ; Bella Canet, Elvira ; Wendling, Arthur ; Floyd, Royce W.</creator><creatorcontrib>Sadhasivam, Kavitha ; Bella Canet, Elvira ; Wendling, Arthur ; Floyd, Royce W.</creatorcontrib><description>The high fluidity of lightweight self-consolidating concrete (LWSCC) combined with the tendency for some aggregate particles to collect near the top of the member has the potential to affect bond of prestressing strands with a significant amount of concrete below. Transfer and development length were evaluated for rectangular beam specimens cast with LWSCC and normal weight self-consolidating concrete (SCC). Each member was prestressed with a single 13.3 mm prestressing strand and cast with 300 mm of concrete either above or below the prestressing strand. Strand end slip was used to compare prestress transfer behavior, and measured transfer lengths were compared to the ACI and American Association of State Highway and Transportation Officials (AASHTO) equations. Development length was evaluated using flexural tests with a critical section at the code calculated value. The results of the experimental program indicate an increase in transfer length for strands placed near the top of the members cast with SCC. The ACI/AASHTO equation and AASHTO 60d b expression produced reasonable average predictions for transfer length of bottom strand specimens, but underestimated transfer length for top strand specimens. Flexural tests indicated a development length larger than the value predicted using the ACI and AASHTO code equations for specimens with 300 mm of concrete below.</description><identifier>ISSN: 2470-5314</identifier><identifier>EISSN: 2470-5322</identifier><identifier>DOI: 10.1080/24705314.2017.1280588</identifier><language>eng</language><publisher>Taylor &amp; Francis</publisher><subject>bond ; Lightweight ; self-consolidating concrete ; transfer length</subject><ispartof>Journal of structural integrity and maintenance, 2017-01, Vol.2 (1), p.39-47</ispartof><rights>2017 Korea Institute for Structural Maintenance and Inspection 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c240t-8b2969fe0388b27d22445b0449f92348d16d0c13dfc3d50b4bc561b62d93bb443</citedby><cites>FETCH-LOGICAL-c240t-8b2969fe0388b27d22445b0449f92348d16d0c13dfc3d50b4bc561b62d93bb443</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,783,787,27936,27937</link.rule.ids></links><search><creatorcontrib>Sadhasivam, Kavitha</creatorcontrib><creatorcontrib>Bella Canet, Elvira</creatorcontrib><creatorcontrib>Wendling, Arthur</creatorcontrib><creatorcontrib>Floyd, Royce W.</creatorcontrib><title>Effect of vertical strand location on bond performance of prestressing strands cast in lightweight self-consolidating concrete</title><title>Journal of structural integrity and maintenance</title><description>The high fluidity of lightweight self-consolidating concrete (LWSCC) combined with the tendency for some aggregate particles to collect near the top of the member has the potential to affect bond of prestressing strands with a significant amount of concrete below. Transfer and development length were evaluated for rectangular beam specimens cast with LWSCC and normal weight self-consolidating concrete (SCC). Each member was prestressed with a single 13.3 mm prestressing strand and cast with 300 mm of concrete either above or below the prestressing strand. Strand end slip was used to compare prestress transfer behavior, and measured transfer lengths were compared to the ACI and American Association of State Highway and Transportation Officials (AASHTO) equations. Development length was evaluated using flexural tests with a critical section at the code calculated value. The results of the experimental program indicate an increase in transfer length for strands placed near the top of the members cast with SCC. The ACI/AASHTO equation and AASHTO 60d b expression produced reasonable average predictions for transfer length of bottom strand specimens, but underestimated transfer length for top strand specimens. Flexural tests indicated a development length larger than the value predicted using the ACI and AASHTO code equations for specimens with 300 mm of concrete below.</description><subject>bond</subject><subject>Lightweight</subject><subject>self-consolidating concrete</subject><subject>transfer length</subject><issn>2470-5314</issn><issn>2470-5322</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNp9UNtKAzEQDaJgqf0EIT-wNdft7ptSqhYKvuhzyLVG0k1JgqUvfrtZW30UhpkzwzkH5gBwi9Ecow7dEbZAnGI2Jwgv5ph0iHfdBZiM94ZTQi7_MGbXYJbzB0IIt5y1DE_A18o5qwuMDn7aVLyWAeaS5GBgiFoWHwdYS8V62NvkYtrJQduRv0-2Mm3OftieNRlqmQv0Awx--14Oduww2-AaHYccgzfVstLrppMt9gZcORmynZ3nFLw9rl6Xz83m5Wm9fNg0mjBUmk6Rvu2dRbSrcGEIYYwrxFjvekJZZ3BrkMbUOE0NR4opzVusWmJ6qhRjdAr4yVenmHOyTuyT38l0FBiJMUfxm6MYcxTnHKvu_qTzw8_rh5iCEUUeQ0yufqx9FvR_i28Pf3xD</recordid><startdate>20170102</startdate><enddate>20170102</enddate><creator>Sadhasivam, Kavitha</creator><creator>Bella Canet, Elvira</creator><creator>Wendling, Arthur</creator><creator>Floyd, Royce W.</creator><general>Taylor &amp; Francis</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20170102</creationdate><title>Effect of vertical strand location on bond performance of prestressing strands cast in lightweight self-consolidating concrete</title><author>Sadhasivam, Kavitha ; Bella Canet, Elvira ; Wendling, Arthur ; Floyd, Royce W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c240t-8b2969fe0388b27d22445b0449f92348d16d0c13dfc3d50b4bc561b62d93bb443</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>bond</topic><topic>Lightweight</topic><topic>self-consolidating concrete</topic><topic>transfer length</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sadhasivam, Kavitha</creatorcontrib><creatorcontrib>Bella Canet, Elvira</creatorcontrib><creatorcontrib>Wendling, Arthur</creatorcontrib><creatorcontrib>Floyd, Royce W.</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of structural integrity and maintenance</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sadhasivam, Kavitha</au><au>Bella Canet, Elvira</au><au>Wendling, Arthur</au><au>Floyd, Royce W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of vertical strand location on bond performance of prestressing strands cast in lightweight self-consolidating concrete</atitle><jtitle>Journal of structural integrity and maintenance</jtitle><date>2017-01-02</date><risdate>2017</risdate><volume>2</volume><issue>1</issue><spage>39</spage><epage>47</epage><pages>39-47</pages><issn>2470-5314</issn><eissn>2470-5322</eissn><abstract>The high fluidity of lightweight self-consolidating concrete (LWSCC) combined with the tendency for some aggregate particles to collect near the top of the member has the potential to affect bond of prestressing strands with a significant amount of concrete below. Transfer and development length were evaluated for rectangular beam specimens cast with LWSCC and normal weight self-consolidating concrete (SCC). Each member was prestressed with a single 13.3 mm prestressing strand and cast with 300 mm of concrete either above or below the prestressing strand. Strand end slip was used to compare prestress transfer behavior, and measured transfer lengths were compared to the ACI and American Association of State Highway and Transportation Officials (AASHTO) equations. Development length was evaluated using flexural tests with a critical section at the code calculated value. The results of the experimental program indicate an increase in transfer length for strands placed near the top of the members cast with SCC. The ACI/AASHTO equation and AASHTO 60d b expression produced reasonable average predictions for transfer length of bottom strand specimens, but underestimated transfer length for top strand specimens. Flexural tests indicated a development length larger than the value predicted using the ACI and AASHTO code equations for specimens with 300 mm of concrete below.</abstract><pub>Taylor &amp; Francis</pub><doi>10.1080/24705314.2017.1280588</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2470-5314
ispartof Journal of structural integrity and maintenance, 2017-01, Vol.2 (1), p.39-47
issn 2470-5314
2470-5322
language eng
recordid cdi_crossref_primary_10_1080_24705314_2017_1280588
source Taylor and Francis Science and Technology Collection
subjects bond
Lightweight
self-consolidating concrete
transfer length
title Effect of vertical strand location on bond performance of prestressing strands cast in lightweight self-consolidating concrete
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-11-11T14%3A53%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_infor&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20vertical%20strand%20location%20on%20bond%20performance%20of%20prestressing%20strands%20cast%20in%20lightweight%20self-consolidating%20concrete&rft.jtitle=Journal%20of%20structural%20integrity%20and%20maintenance&rft.au=Sadhasivam,%20Kavitha&rft.date=2017-01-02&rft.volume=2&rft.issue=1&rft.spage=39&rft.epage=47&rft.pages=39-47&rft.issn=2470-5314&rft.eissn=2470-5322&rft_id=info:doi/10.1080/24705314.2017.1280588&rft_dat=%3Ccrossref_infor%3E10_1080_24705314_2017_1280588%3C/crossref_infor%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c240t-8b2969fe0388b27d22445b0449f92348d16d0c13dfc3d50b4bc561b62d93bb443%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true