Loading…

On-line sorption preconcentration and FIA-FAAS determination of palladium and platinum in solution

A flow injection flame atomic absorption method for palladium and platinum determination in solution, including sorption preconcentration, has been developed. Preconcentration of platinum metals as ionic associates with n-octyldiethylenetriamine was carried out on ‘reversed phase’ styrene–divinylben...

Full description

Saved in:
Bibliographic Details
Published in:Mendeleev communications 1998, Vol.8 (5), p.171-173
Main Authors: Bogacheva, Lubov’ V., Kovalev, Igor A., Tsysin, Grigory I., Formanovsky, Andrew A., Zolotov, Yury A.
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c313t-7f0eac57baabcaefe48041e520ad94d3a0e24e2a6455749f2b74c0fc67e931ee3
cites cdi_FETCH-LOGICAL-c313t-7f0eac57baabcaefe48041e520ad94d3a0e24e2a6455749f2b74c0fc67e931ee3
container_end_page 173
container_issue 5
container_start_page 171
container_title Mendeleev communications
container_volume 8
creator Bogacheva, Lubov’ V.
Kovalev, Igor A.
Tsysin, Grigory I.
Formanovsky, Andrew A.
Zolotov, Yury A.
description A flow injection flame atomic absorption method for palladium and platinum determination in solution, including sorption preconcentration, has been developed. Preconcentration of platinum metals as ionic associates with n-octyldiethylenetriamine was carried out on ‘reversed phase’ styrene–divinylbenzene copolymer SSPS. RSD 0.03–0.08, detection limits 5 and 3 mg l –1 (Pd and Pt) for 1 min of preconcentration and sampling frequency up to 40 h –1 were achieved.
doi_str_mv 10.1070/MC1998v008n05ABEH000959
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1070_MC1998v008n05ABEH000959</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0959943698711526</els_id><sourcerecordid>S0959943698711526</sourcerecordid><originalsourceid>FETCH-LOGICAL-c313t-7f0eac57baabcaefe48041e520ad94d3a0e24e2a6455749f2b74c0fc67e931ee3</originalsourceid><addsrcrecordid>eNqFUMtOAjEU7UITEf0G5wdGb6ctpcuRgJBgWKjrSae9TWqGzqQdSPx7C7glrk7ueeXmEPJE4ZmChJf3BVVqfgSYBxD163INAEqoGzI5Qak4m92R-5S-My8FoxPS7kLZ-YBF6uMw-j4UQ0TTB4NhjPpM6GCL1aYuV3X9UVgcMe59uEi9Kwbdddr6w_7sG7oshHz4kBu7w8n1QG6d7hI-_uGUfK2Wn4t1ud29bRb1tjSMsrGUDlAbIVutW6PRIZ8Dpygq0FZxyzRgxbHSMy6E5MpVreQGnJlJVIwisimRl14T-5QiumaIfq_jT0OhOc3TXJknJ-tLEvN7R4-xScZj3sD6PMbY2N7_2_ELPFFykg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>On-line sorption preconcentration and FIA-FAAS determination of palladium and platinum in solution</title><source>ScienceDirect Freedom Collection</source><creator>Bogacheva, Lubov’ V. ; Kovalev, Igor A. ; Tsysin, Grigory I. ; Formanovsky, Andrew A. ; Zolotov, Yury A.</creator><creatorcontrib>Bogacheva, Lubov’ V. ; Kovalev, Igor A. ; Tsysin, Grigory I. ; Formanovsky, Andrew A. ; Zolotov, Yury A.</creatorcontrib><description>A flow injection flame atomic absorption method for palladium and platinum determination in solution, including sorption preconcentration, has been developed. Preconcentration of platinum metals as ionic associates with n-octyldiethylenetriamine was carried out on ‘reversed phase’ styrene–divinylbenzene copolymer SSPS. RSD 0.03–0.08, detection limits 5 and 3 mg l –1 (Pd and Pt) for 1 min of preconcentration and sampling frequency up to 40 h –1 were achieved.</description><identifier>ISSN: 0959-9436</identifier><identifier>DOI: 10.1070/MC1998v008n05ABEH000959</identifier><language>eng</language><publisher>Elsevier B.V</publisher><ispartof>Mendeleev communications, 1998, Vol.8 (5), p.171-173</ispartof><rights>1998 jointly by The Russian Academy of Sciences and The Royal Society of Chemistry (Turpion Ltd)</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c313t-7f0eac57baabcaefe48041e520ad94d3a0e24e2a6455749f2b74c0fc67e931ee3</citedby><cites>FETCH-LOGICAL-c313t-7f0eac57baabcaefe48041e520ad94d3a0e24e2a6455749f2b74c0fc67e931ee3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,786,790,4043,27956,27957,27958</link.rule.ids></links><search><creatorcontrib>Bogacheva, Lubov’ V.</creatorcontrib><creatorcontrib>Kovalev, Igor A.</creatorcontrib><creatorcontrib>Tsysin, Grigory I.</creatorcontrib><creatorcontrib>Formanovsky, Andrew A.</creatorcontrib><creatorcontrib>Zolotov, Yury A.</creatorcontrib><title>On-line sorption preconcentration and FIA-FAAS determination of palladium and platinum in solution</title><title>Mendeleev communications</title><description>A flow injection flame atomic absorption method for palladium and platinum determination in solution, including sorption preconcentration, has been developed. Preconcentration of platinum metals as ionic associates with n-octyldiethylenetriamine was carried out on ‘reversed phase’ styrene–divinylbenzene copolymer SSPS. RSD 0.03–0.08, detection limits 5 and 3 mg l –1 (Pd and Pt) for 1 min of preconcentration and sampling frequency up to 40 h –1 were achieved.</description><issn>0959-9436</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFUMtOAjEU7UITEf0G5wdGb6ctpcuRgJBgWKjrSae9TWqGzqQdSPx7C7glrk7ueeXmEPJE4ZmChJf3BVVqfgSYBxD163INAEqoGzI5Qak4m92R-5S-My8FoxPS7kLZ-YBF6uMw-j4UQ0TTB4NhjPpM6GCL1aYuV3X9UVgcMe59uEi9Kwbdddr6w_7sG7oshHz4kBu7w8n1QG6d7hI-_uGUfK2Wn4t1ud29bRb1tjSMsrGUDlAbIVutW6PRIZ8Dpygq0FZxyzRgxbHSMy6E5MpVreQGnJlJVIwisimRl14T-5QiumaIfq_jT0OhOc3TXJknJ-tLEvN7R4-xScZj3sD6PMbY2N7_2_ELPFFykg</recordid><startdate>1998</startdate><enddate>1998</enddate><creator>Bogacheva, Lubov’ V.</creator><creator>Kovalev, Igor A.</creator><creator>Tsysin, Grigory I.</creator><creator>Formanovsky, Andrew A.</creator><creator>Zolotov, Yury A.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>1998</creationdate><title>On-line sorption preconcentration and FIA-FAAS determination of palladium and platinum in solution</title><author>Bogacheva, Lubov’ V. ; Kovalev, Igor A. ; Tsysin, Grigory I. ; Formanovsky, Andrew A. ; Zolotov, Yury A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c313t-7f0eac57baabcaefe48041e520ad94d3a0e24e2a6455749f2b74c0fc67e931ee3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bogacheva, Lubov’ V.</creatorcontrib><creatorcontrib>Kovalev, Igor A.</creatorcontrib><creatorcontrib>Tsysin, Grigory I.</creatorcontrib><creatorcontrib>Formanovsky, Andrew A.</creatorcontrib><creatorcontrib>Zolotov, Yury A.</creatorcontrib><collection>CrossRef</collection><jtitle>Mendeleev communications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bogacheva, Lubov’ V.</au><au>Kovalev, Igor A.</au><au>Tsysin, Grigory I.</au><au>Formanovsky, Andrew A.</au><au>Zolotov, Yury A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On-line sorption preconcentration and FIA-FAAS determination of palladium and platinum in solution</atitle><jtitle>Mendeleev communications</jtitle><date>1998</date><risdate>1998</risdate><volume>8</volume><issue>5</issue><spage>171</spage><epage>173</epage><pages>171-173</pages><issn>0959-9436</issn><abstract>A flow injection flame atomic absorption method for palladium and platinum determination in solution, including sorption preconcentration, has been developed. Preconcentration of platinum metals as ionic associates with n-octyldiethylenetriamine was carried out on ‘reversed phase’ styrene–divinylbenzene copolymer SSPS. RSD 0.03–0.08, detection limits 5 and 3 mg l –1 (Pd and Pt) for 1 min of preconcentration and sampling frequency up to 40 h –1 were achieved.</abstract><pub>Elsevier B.V</pub><doi>10.1070/MC1998v008n05ABEH000959</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0959-9436
ispartof Mendeleev communications, 1998, Vol.8 (5), p.171-173
issn 0959-9436
language eng
recordid cdi_crossref_primary_10_1070_MC1998v008n05ABEH000959
source ScienceDirect Freedom Collection
title On-line sorption preconcentration and FIA-FAAS determination of palladium and platinum in solution
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-09-22T21%3A18%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On-line%20sorption%20preconcentration%20and%20FIA-FAAS%20determination%20of%20palladium%20and%20platinum%20in%20solution&rft.jtitle=Mendeleev%20communications&rft.au=Bogacheva,%20Lubov%E2%80%99%20V.&rft.date=1998&rft.volume=8&rft.issue=5&rft.spage=171&rft.epage=173&rft.pages=171-173&rft.issn=0959-9436&rft_id=info:doi/10.1070/MC1998v008n05ABEH000959&rft_dat=%3Celsevier_cross%3ES0959943698711526%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c313t-7f0eac57baabcaefe48041e520ad94d3a0e24e2a6455749f2b74c0fc67e931ee3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true