Loading…
Radiation hard 3D silicon pixel sensors for use in the ATLAS detector at the HL-LHC
The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation fluences above 1 × 1016 neqcm-2. Novel 3D silicon pixel sensors o...
Saved in:
Main Authors: | , , , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | |
container_start_page | |
container_title | |
container_volume | |
creator | Heggelund, Andreas Huiberts, Simon Kristian Dorholt, Ole Read, Alexander Lincoln Røhne, Ole Myren Sandaker, Heidi Lauritzen, Magne Eik Stugu, Bjarne Sandvik Kok, Angela Koybasi, Ozhan Povoli, Marco Bomben, M Lange, J Rummler, André |
description | The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation fluences above 1 × 1016 neqcm-2. Novel 3D silicon pixel sensors offer a superior radiation tolerance compared to conventional planar pixel sensors, and are thus excellent candidates for the innermost parts of the ITk. This paper presents studies of 3D pixel sensors with pixel size 50 × 50 μm2 mounted on the RD53A prototype readout chip. Following a description of the design and fabrication steps, Test Beam results are presented for unirradiated as well as heavily irradiated sensors. For particles passing at perpendicular incidence, it is shown that average efficiencies above 96% are reached for sensors exposed to fluences of 1 × 1016 neqcm-2 when biased to 80 V. |
format | article |
fullrecord | <record><control><sourceid>cristin_3HK</sourceid><recordid>TN_cdi_cristin_nora_11250_3042082</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>11250_3042082</sourcerecordid><originalsourceid>FETCH-cristin_nora_11250_30420823</originalsourceid><addsrcrecordid>eNqNikEKwjAQRbNxIeodxgMU0kTBbalKFlnZ7kNopnQgJJKJ4PEt4gFcfd57fyuGhw_kK-UEiy8B9BWYIk0rP-mNERgT58Iw5wIvRqAEdUHoRtsNELDiVNfi69ca21jT78Vm9pHx8NudON5vY2-aqRBXSi7l4l3bqrN0Wp6UvCj9z-cDNBA1hg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Radiation hard 3D silicon pixel sensors for use in the ATLAS detector at the HL-LHC</title><source>NORA - Norwegian Open Research Archives</source><creator>Heggelund, Andreas ; Huiberts, Simon Kristian ; Dorholt, Ole ; Read, Alexander Lincoln ; Røhne, Ole Myren ; Sandaker, Heidi ; Lauritzen, Magne Eik ; Stugu, Bjarne Sandvik ; Kok, Angela ; Koybasi, Ozhan ; Povoli, Marco ; Bomben, M ; Lange, J ; Rummler, André</creator><creatorcontrib>Heggelund, Andreas ; Huiberts, Simon Kristian ; Dorholt, Ole ; Read, Alexander Lincoln ; Røhne, Ole Myren ; Sandaker, Heidi ; Lauritzen, Magne Eik ; Stugu, Bjarne Sandvik ; Kok, Angela ; Koybasi, Ozhan ; Povoli, Marco ; Bomben, M ; Lange, J ; Rummler, André</creatorcontrib><description>The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation fluences above 1 × 1016 neqcm-2. Novel 3D silicon pixel sensors offer a superior radiation tolerance compared to conventional planar pixel sensors, and are thus excellent candidates for the innermost parts of the ITk. This paper presents studies of 3D pixel sensors with pixel size 50 × 50 μm2 mounted on the RD53A prototype readout chip. Following a description of the design and fabrication steps, Test Beam results are presented for unirradiated as well as heavily irradiated sensors. For particles passing at perpendicular incidence, it is shown that average efficiencies above 96% are reached for sensors exposed to fluences of 1 × 1016 neqcm-2 when biased to 80 V.</description><language>eng</language><publisher>IOP Publishing</publisher><creationdate>2022</creationdate><rights>info:eu-repo/semantics/openAccess</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,786,891,26600</link.rule.ids><linktorsrc>$$Uhttp://hdl.handle.net/11250/3042082$$EView_record_in_NORA$$FView_record_in_$$GNORA$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Heggelund, Andreas</creatorcontrib><creatorcontrib>Huiberts, Simon Kristian</creatorcontrib><creatorcontrib>Dorholt, Ole</creatorcontrib><creatorcontrib>Read, Alexander Lincoln</creatorcontrib><creatorcontrib>Røhne, Ole Myren</creatorcontrib><creatorcontrib>Sandaker, Heidi</creatorcontrib><creatorcontrib>Lauritzen, Magne Eik</creatorcontrib><creatorcontrib>Stugu, Bjarne Sandvik</creatorcontrib><creatorcontrib>Kok, Angela</creatorcontrib><creatorcontrib>Koybasi, Ozhan</creatorcontrib><creatorcontrib>Povoli, Marco</creatorcontrib><creatorcontrib>Bomben, M</creatorcontrib><creatorcontrib>Lange, J</creatorcontrib><creatorcontrib>Rummler, André</creatorcontrib><title>Radiation hard 3D silicon pixel sensors for use in the ATLAS detector at the HL-LHC</title><description>The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation fluences above 1 × 1016 neqcm-2. Novel 3D silicon pixel sensors offer a superior radiation tolerance compared to conventional planar pixel sensors, and are thus excellent candidates for the innermost parts of the ITk. This paper presents studies of 3D pixel sensors with pixel size 50 × 50 μm2 mounted on the RD53A prototype readout chip. Following a description of the design and fabrication steps, Test Beam results are presented for unirradiated as well as heavily irradiated sensors. For particles passing at perpendicular incidence, it is shown that average efficiencies above 96% are reached for sensors exposed to fluences of 1 × 1016 neqcm-2 when biased to 80 V.</description><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>3HK</sourceid><recordid>eNqNikEKwjAQRbNxIeodxgMU0kTBbalKFlnZ7kNopnQgJJKJ4PEt4gFcfd57fyuGhw_kK-UEiy8B9BWYIk0rP-mNERgT58Iw5wIvRqAEdUHoRtsNELDiVNfi69ca21jT78Vm9pHx8NudON5vY2-aqRBXSi7l4l3bqrN0Wp6UvCj9z-cDNBA1hg</recordid><startdate>2022</startdate><enddate>2022</enddate><creator>Heggelund, Andreas</creator><creator>Huiberts, Simon Kristian</creator><creator>Dorholt, Ole</creator><creator>Read, Alexander Lincoln</creator><creator>Røhne, Ole Myren</creator><creator>Sandaker, Heidi</creator><creator>Lauritzen, Magne Eik</creator><creator>Stugu, Bjarne Sandvik</creator><creator>Kok, Angela</creator><creator>Koybasi, Ozhan</creator><creator>Povoli, Marco</creator><creator>Bomben, M</creator><creator>Lange, J</creator><creator>Rummler, André</creator><general>IOP Publishing</general><scope>3HK</scope></search><sort><creationdate>2022</creationdate><title>Radiation hard 3D silicon pixel sensors for use in the ATLAS detector at the HL-LHC</title><author>Heggelund, Andreas ; Huiberts, Simon Kristian ; Dorholt, Ole ; Read, Alexander Lincoln ; Røhne, Ole Myren ; Sandaker, Heidi ; Lauritzen, Magne Eik ; Stugu, Bjarne Sandvik ; Kok, Angela ; Koybasi, Ozhan ; Povoli, Marco ; Bomben, M ; Lange, J ; Rummler, André</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-cristin_nora_11250_30420823</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Heggelund, Andreas</creatorcontrib><creatorcontrib>Huiberts, Simon Kristian</creatorcontrib><creatorcontrib>Dorholt, Ole</creatorcontrib><creatorcontrib>Read, Alexander Lincoln</creatorcontrib><creatorcontrib>Røhne, Ole Myren</creatorcontrib><creatorcontrib>Sandaker, Heidi</creatorcontrib><creatorcontrib>Lauritzen, Magne Eik</creatorcontrib><creatorcontrib>Stugu, Bjarne Sandvik</creatorcontrib><creatorcontrib>Kok, Angela</creatorcontrib><creatorcontrib>Koybasi, Ozhan</creatorcontrib><creatorcontrib>Povoli, Marco</creatorcontrib><creatorcontrib>Bomben, M</creatorcontrib><creatorcontrib>Lange, J</creatorcontrib><creatorcontrib>Rummler, André</creatorcontrib><collection>NORA - Norwegian Open Research Archives</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Heggelund, Andreas</au><au>Huiberts, Simon Kristian</au><au>Dorholt, Ole</au><au>Read, Alexander Lincoln</au><au>Røhne, Ole Myren</au><au>Sandaker, Heidi</au><au>Lauritzen, Magne Eik</au><au>Stugu, Bjarne Sandvik</au><au>Kok, Angela</au><au>Koybasi, Ozhan</au><au>Povoli, Marco</au><au>Bomben, M</au><au>Lange, J</au><au>Rummler, André</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radiation hard 3D silicon pixel sensors for use in the ATLAS detector at the HL-LHC</atitle><date>2022</date><risdate>2022</risdate><notes>Journal of Instrumentation (JINST). 2022, 17 (8), P08003.</notes><abstract>The High Luminosity LHC (HL-LHC) upgrade requires the planned Inner Tracker (ITk) of the ATLAS detector to tolerate extremely high radiation doses. Specifically, the innermost parts of the pixel system will have to withstand radiation fluences above 1 × 1016 neqcm-2. Novel 3D silicon pixel sensors offer a superior radiation tolerance compared to conventional planar pixel sensors, and are thus excellent candidates for the innermost parts of the ITk. This paper presents studies of 3D pixel sensors with pixel size 50 × 50 μm2 mounted on the RD53A prototype readout chip. Following a description of the design and fabrication steps, Test Beam results are presented for unirradiated as well as heavily irradiated sensors. For particles passing at perpendicular incidence, it is shown that average efficiencies above 96% are reached for sensors exposed to fluences of 1 × 1016 neqcm-2 when biased to 80 V.</abstract><pub>IOP Publishing</pub><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | |
ispartof | |
issn | |
language | eng |
recordid | cdi_cristin_nora_11250_3042082 |
source | NORA - Norwegian Open Research Archives |
title | Radiation hard 3D silicon pixel sensors for use in the ATLAS detector at the HL-LHC |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-09-21T12%3A31%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-cristin_3HK&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radiation%20hard%203D%20silicon%20pixel%20sensors%20for%20use%20in%20the%20ATLAS%20detector%20at%20the%20HL-LHC&rft.au=Heggelund,%20Andreas&rft.date=2022&rft_id=info:doi/&rft_dat=%3Ccristin_3HK%3E11250_3042082%3C/cristin_3HK%3E%3Cgrp_id%3Ecdi_FETCH-cristin_nora_11250_30420823%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |